RENEWABLE ENERGY | 卷:89 |
Blade pitch control malfunction simulation in a wind energy conversion system with MPC five-level converter | |
Article | |
Seixas, M.1,2,3  Melicio, R.1,2  Mendes, V. M. F.2,3  Couto, C.4  | |
[1] Univ Lisbon, Inst Super Tecn, IDMEC LAETA, P-1699 Lisbon, Portugal | |
[2] Univ Evora, Escola Ciencias & Tecnol, Dept Fis, Evora, Portugal | |
[3] Inst Super Engn Lisboa, Dept Elect Engn & Automat, Lisbon, Portugal | |
[4] Univ Minho, Ctr Algoritmi, Guimaraes, Portugal | |
关键词: Wind energy; Five-level power converter; Drive train; Fractional-order control; Simulation; | |
DOI : 10.1016/j.renene.2015.12.005 | |
来源: Elsevier | |
【 摘 要 】
This paper is on a wind energy conversion system simulation of a transient analysis due to a blade pitch control malfunction. The aim of the transient analysis is the study of the behavior of a back-to-back multiple point clamped five-level full-power converter implemented in a wind energy conversion system equipped with a permanent magnet synchronous generator. An alternate current link connects the system to the grid. The drive train is modeled by a three-mass model in order to simulate the dynamic effect of the wind on the tower. The control strategy is based on fractional-order control. Unbalance voltages in the DC-link capacitors are lessen due to the control strategy, balancing the capacitor banks voltages by a selection of the output voltage vectors. Simulation studies are carried out to evaluate not only the system behavior, but also the quality of the energy injected into the electric grid. (C) 2015 Elsevier Ltd. All rights reserved.
【 授权许可】
Free
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
10_1016_j_renene_2015_12_005.pdf | 1787KB | download |