The Science of Making Torque from Wind | |
Comparing the Brushless DFIM to other Generator Systems for Wind Turbine Drive-Trains | |
Strous, Tim D.^1 ; Shipurkar, Udai^1 ; Polinder, Henk^1 ; Ferreira, Jan A.^1 | |
Delft University of Technology, Department of Electrical Sustainable Energy, Delft, Netherlands^1 | |
关键词: Capital expenditures; Direct drive; Drive train; Fe-based; Feasible alternatives; Generator design; Generator systems; PM generator; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/753/11/112014/pdf DOI : 10.1088/1742-6596/753/11/112014 |
|
来源: IOP | |
【 摘 要 】
In this paper, the brushless DFIM based wind turbine drive-train topology is compared to the DFIG based and PM generator based drive-train topologies, that are most commonly applied in modern wind turbines. The comparison will be based on a 3.2 MW case study wind turbine. By using FE based multi-objective optimization, optimized generator designs for the different topologies are generated. Then the capital expenditures of the resulting drive-train topologies are calculated and compared. Additionally, wind turbine drive-train configurations with 1, 2 and 3 stage gearboxes as well as a direct-drive configuration are taken into account. The resulting comparison shows that the brushless DFIM based drive-train with a 2 stage gearbox configuration provides a feasible alternative in commercial wind turbine drive-train applications.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Comparing the Brushless DFIM to other Generator Systems for Wind Turbine Drive-Trains | 1083KB | download |