Gas permeability, wettability and morphology of gas diffusion layers before and after performing a realistic ex-situ compression test
Article
Aldakheel, F.1  Ismail, M. S.1  Hughes, K. J.1  Ingham, D. B.1  Ma, L.1  Pourkashanian, M.1  Cumming, D.2  Smith, R.2 
[1] Univ Sheffield, Dept Mech Engn, Energy 2050, Sheffield S3 7RD, S Yorkshire, England
[2] Univ Sheffield, Dept Chem & Biol Engn, Sheffield S1 3JD, S Yorkshire, England
关键词: PEM fuel cells;    Gas diffusion layers;    Compression;    Gas permeability;    Contact angle;    MPL penetration;   
DOI  :  10.1016/j.renene.2019.11.109
来源: Elsevier
PDF
【 摘 要 】

The through-plane gas permeability, wettability, thickness and morphology have been investigated before and after a compression test, which is important to the GDL design. The compression tests were designed to simulate the initial assembling compression and the cycles of loading and unloading arising as a result of hydration/dehydration of the membrane. Owing to the presence of the microporous layer (MFL), the results show that the coated gas diffusion layers (GDLs) are slightly more resistive to deformation than the uncoated GDLs. Amongst all the tested carbon substrates (i.e. the uncoated GDLs), Toray carbon substrate was found to show the least reduction in thickness and gas permeability after compression, and this was attributed to its relatively high density and low porosity. As for the coated GDLs, the level of MPL penetration for one of the tested GDLs (i.e. SGL 35BC) was significantly higher than that of the other GDL (i.e. SGL 34BC), resulting in substantially less reduction in thickness and gas permeability of the former GDL after compression. Finally, the contact angles of all the tested GDL materials were found to decrease after compression due to the decreased surface roughness. (C) 2019 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_renene_2019_11_109.pdf 2154KB PDF download
  文献评价指标  
  下载次数:37次 浏览次数:3次