期刊论文详细信息
International Journal of Behavioral Nutrition and Physical Activity
Accuracy of uploadable pedometers in laboratory, overground, and free-living conditions in young and older adults
Research
Nora E Miller1  Ann M Swartz1  Christopher J Dondzila1  Scott J Strath1  Elizabeth K Lenz2 
[1] Physical Activity and Health Research Laboratory, University of Wisconsin-Milwaukee, P.O. Box 413, 53201, Milwaukee, WI, USA;The College at Brockport, State University of New York, 350 New Campus Dr, 14420, Brockport, NY, USA;
关键词: Walking;    Step-counter;    Precision;    Accuracy;    Motion sensor;   
DOI  :  10.1186/1479-5868-9-143
 received in 2011-11-08, accepted in 2012-11-07,  发布年份 2012
来源: Springer
PDF
【 摘 要 】

PurposeThe purpose of this study was to examine the accuracy of uploadable pedometers to accurately count steps during treadmill (TM) and overground (OG) walking, and during a 24 hour monitoring period (24 hr) under free living conditions in young and older adults.MethodsOne hundred and two participants (n=53 aged 20–49 yrs; n=49 aged 50–80 yrs) completed a TM protocol (53.6, 67.0, 80.4, 93.8, and 107.2 m/min, five minutes for each speed) and an OG walking protocol (self-determined “< normal”, “normal”, and “> normal” walking speeds) while wearing two waist-mounted uploadable pedometers (Omron HJ-720ITC [OM] and Kenz Lifecorder EX [LC]). Actual steps were manually tallied by a researcher. During the 24 hr period, participants wore a New Lifestyles-1000 (NL) pedometer (standard of care) attached to a belt at waist level over the midline of the left thigh, in addition to the LC on the belt over the midline of the right thigh. The following day, the same procedure was conducted, replacing the LC with the OM. One-sample t-tests were performed to compare measured and manually tallied steps during the TM and OG protocols, and between steps quantified by the NL with that of the OM and LC during the 24 hr period. Mean error step scores (MES, criterion – device) and 95% Limits of Agreement (LoA) were calculated.ResultsThere were no significant differences between the OM and tallied steps for any of the TM speeds for either the young or older adult groups. The LC significantly underestimated steps for the young adult group during the 53.6 m/min TM speed (MES 31.4 [14.5, 48.3]) and during the OG < normal walking speed (MES 12.0 [0.9, 23.1] (p<0.01 for both age groups). The LC also significantly underestimated steps for the older adult group during the TM speeds of 53.6 m/min (MES 64.5 [45.6, 83.4]), 67.0 m/min (MES 15.1 [6.1, 24.0]), and 80.4 m/min (MES 3.2 [0.6, 5.9]) (p<0.01 for all speeds), in addition to the OG < normal walking speed (MES 14.7 [−13.3, 42.6] (p<0.01). The OM reported significantly lower steps during the 24 hr period for the young adult group by 949.1 steps (t=6.111, p<0.025) and for the older adult group by 612.9 steps (t=2.397, p<0.025).ConclusionBoth the OM and LC pedometers were more accurate as TM and OG walking speed increased. The OM significantly underestimated steps during the 24 hr compared with a standard of care evaluation. Overall, both uploadable pedometers appear acceptable to use in young or old age groups to measure walking behavior.

【 授权许可】

CC BY   
© Dondzila et al.; licensee BioMed Central Ltd. 2012

【 预 览 】
附件列表
Files Size Format View
RO202311109140768ZK.pdf 357KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  文献评价指标  
  下载次数:3次 浏览次数:0次