期刊论文详细信息
BMC Musculoskeletal Disorders
Reliability of spatiotemporal and kinetic gait parameters determined by a new instrumented treadmill system
Scott C Wearing1  Stephen R Urry2  Lloyd F Reed2 
[1] Centre of Excellence for Applied Sport Science Research, Queensland Academy of Sport, PO Box 956, Sunnybank, 4109 Queensland, Australia;Institute of Health and Biomedical Innovation, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, 4059 Queensland, Australia
关键词: Reproducibility;    Precision;    Repeatability;    Measurement;    Walking;    Gait analysis;   
Others  :  1129876
DOI  :  10.1186/1471-2474-14-249
 received in 2013-01-08, accepted in 2013-08-14,  发布年份 2013
PDF
【 摘 要 】

Background

Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction force parameters measured by a treadmill system instrumented with a capacitance–based pressure platform.

Methods

Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient.

Results

There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N.

Conclusions

The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.

【 授权许可】

   
2013 Reed et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150226124654799.pdf 587KB PDF download
Figure 3. 93KB Image download
Figure 2. 47KB Image download
Figure 1. 157KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

【 参考文献 】
  • [1]Dean CM, Ada L, Bampton J, Morris ME, Katrak PH, Potts S: Treadmill walking with body weight support in subacute non-ambulatory stroke improves walking capacity more than overground walking: a randomised trial. J Geophys Res 2010, 56(2):97-103.
  • [2]Yen SC, Schmit BD, Landry JM, Roth H, Wu M: Locomotor adaptation to resistance during treadmill training transfers to overground walking in human SCI. Exp Brain Res 2012, 216(3):473-482.
  • [3]Mehrholz J, Friis R, Kugler J, Twork S, Storch A, Pohl M: Treadmill training for patients with parkinson’s disease. Cochrane Database Syst Rev 2010., CD007830
  • [4]Dingwell JB, Davis BL: A rehabilitation treadmill with software for providing real-time gait analysis and visual feedback. J Biomech Eng 1996, 118:253-255.
  • [5]Belli A, Bui P, Berger A, Geyssant A, Lacour JR: A treadmill ergometer for three-dimensional ground reaction forces measurement during walking. J Biomech 2001, 34:105-112.
  • [6]Kram R, Powell AJ: A treadmill-mounted force platform. J Appl Physiol 1989, 67:1692-1698.
  • [7]Kesar TM, Binder-Macleod SA, Hicks GE, Reisman DS: Minimal detectable change for gait variables collected during treadmill walking in individuals post-stroke. Gait Posture 2011, 33(2):314-317.
  • [8]Masani K, Kouzaki M, Fukunaga T: Variability for temporal gait parameters and peak vertical ground reaction forces during treadmill walking. J Appl Physiol 2002, 92:1885-1890.
  • [9]Terrier P, Dériaz O: Kinematic variability, fractal dynamics and local dynamic stability of treadmill walking. J Neuroeng Rehabil 2011, 8:12. BioMed Central Full Text
  • [10]Terrier P: Step-to-Step variability in treadmill walking: influence of rhythmic auditory cueing. PLoS ONE 2012, 7(10):e47171.
  • [11]Luessi F, Mueller LK, Breimhorst M, Vogt T: Influence of visual cues on gait in Parkinson's disease during treadmill walking at multiple velocities. J Neurol Sci 2012, 314:78-82.
  • [12]Wuehr M, Schniepp R, Ilmberger J, Brandt T, Jahn K: Speed-dependent temporospatial gait variability and long-range correlations in cerebellar ataxia. Gait Posture 2013, 37:214-218.
  • [13]Singh A, Kammermeier S, Plate A, Mehrkens JH, Ilmberger J, Bötzel K: Pattern of local field potential activity in the globus pallidus internum of dystonic patients during walking on a treadmill. Exp Neurol 2011, 232:162-167.
  • [14]Granacher U, Wick C, Rueck N, Esposito C, Roth R, Zahner L: Promoting balance and strength in the middle-aged workforce. Int J Sports Med 2011, 32:35-44.
  • [15]Squadrone R, Gallozzi C: Biomechanical and physiological comparison of barefoot and two shod conditions in experienced barefoot runners. J Sports Med Phys Fitness 2009, 49(1):6-13.
  • [16]Zwecker M: Assessing special features of impaired gait after acquired brain injury with an instrumented treadmill. In National Institute of Health Clinical Trials Registery. : ; 2012. ClinicalTrials.gov Identifier: NCT01413321
  • [17]Giacomozzi C, Macellari V: Piezo-dynamometric platform for a more complete analysis of foot-to-floor interaction. IEEE Trans Rehabil Eng 1997, 5(4):322-330.
  • [18]Gong W, Lee S, Kim B: The comparison of pressure of the feet in. stance and gait by the types of bags. J Phys Ther Sci 2010, 22:255-258.
  • [19]Van de Putte M, Hagemeister N, St-Onge N, Parent G, De Guise JA: Habituation to treadmill walking. Biomed Mater Eng 2006, 16(1):43-52.
  • [20]Jordan K, Newell KM: The structure of variability in human walking and running is speed-dependent. Exerc Sport Sci Rev 2008, 36(4):200-204.
  • [21]Hattori T: Current trends in gait analysis: advanced techniques for data acquisition and anlysis. In Biomechanics in Orthopaedics. Edited by Niwa S, Perren SM, Hattori T. Tokyo: Springer-Verlag; 1992:102-120.
  • [22]Weir JP: Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 2005, 19(1):231-240.
  • [23]Bland JM, Altman DG: Measuring agreement in method comparison studies. Stat Methods Med Res 1999, 8(2):135-160.
  • [24]Schmitt JS, Di Fabio RP: Reliable change and minimum important difference (MID) proportions facilitated group responsiveness comparisons using individual threshold criteria. J Clin Epidemiol 2004, 57:1008-1018.
  • [25]Stolze H, Kuhtz-Buschbeck JP, Mondwurf C, Boczek-Funcke A, Jöhnk K, Deuschl G, Illert M: Gait analysis during treadmill and overground locomotion in children and adults. Electroencephalogr Clin Neurophysiol 1997, 105(6):490-497.
  • [26]Paterson KL, Hill KD, Lythgo ND, Maschette W: The reliability of spatiotemporal gait data for young and older women during continuous overground walking. Arch Phys Med Rehabil 2008, 89(12):2360-2365.
  • [27]Owings TM, Grabiner MD: Variability of step kinematics in young and older adults. Gait Posture 2004, 20(1):26-29.
  • [28]Faude O, Donath L, Roth R, Fricker L, Zahner L: Reliability of gait parameters during treadmill walking in community-dwelling healthy seniors. Gait Posture 2012, 36:444-448.
  • [29]Kang HG, Dingwell JB: Separating the effects of age and walking speed on gait variability. Gait Posture 2008, 27(4):572-577.
  • [30]Keller TS, Weisberger AM, Ray JL, Hasan SS, Shiavi RG, Spengler DM: Relationship between vertical ground reaction force and speed during walking, slow jogging, and running. Clin Biomech 1996, 11(5):253-259.
  • [31]Wall JC, Charteris J: A kinematic study of long-term habituation to treadmill walking. Ergonomics 1981, 24:531-542.
  • [32]Jordan K, Challis JH, Newell KM: Walking speed influences on gait cycle variability. Gait Posture 2007, 26:128-134.
  • [33]Mak MK: Reduced step length, not step length variability is central to gait hypokinesia in people with Parkinson's disease. Clin Neurol Neurosurg 2013, 115(5):587-590.
  • [34]Maki BE: Gait changes in older adults: predictors of falls or indicators of fear. J Am Geriatr Soc 1997, 45(3):313-320.
  文献评价指标  
  下载次数:33次 浏览次数:14次