期刊论文详细信息
Reproductive Biology and Endocrinology
Phase I, two-way, crossover study to demonstrate bioequivalence and to compare safety and tolerability of single-dose XM17 vs Gonal-f® in healthy women after follicle-stimulating hormone downregulation
Research
Andreas Lammerich1  Peter Bias1  Arnd Mueller1 
[1] Merckle GmbH, Member of the Teva Group, Graf-Arco-Str. 3, 89079, Ulm, Germany;
关键词: Recombinant human follicle-stimulating hormone;    Infertility;    Pharmacokinetics;   
DOI  :  10.1186/s12958-015-0124-y
 received in 2015-07-08, accepted in 2015-08-20,  发布年份 2015
来源: Springer
PDF
【 摘 要 】

BackgroundXM17 is a recombinant human follicle-stimulating hormone (rhFSH) intended mainly for use in controlled ovarian hyperstimulation and the treatment of anovulation. The purpose of the current study was to establish bioequivalence, safety and tolerability of single 300-IU subcutaneous (sc) doses of XM17 to that of the reference follitropin alfa (Gonal-f®) in healthy young women.MethodsThis open-label, Phase I, single-dose, single-center, two-way crossover study was conducted from February to May 2009. Thirty-six women aged 18–39 years were included, with a study duration of ~27 days per participant. After endogenous FSH downregulation with goserelin (3.6 mg) on study Day 0, XM17 and Gonal-f® were administered on Days 11 and 19 in random sequence. Frequent serum samples were drawn for standard pharmacokinetics until 168 h postdosing. Laboratory values, adverse events (AEs) and local tolerability were assessed throughout the study period. Primary endpoints included Cmax and AUC0-t. Secondary endpoints included additional pharmacokinetic (PK) parameters, safety and tolerability.ResultsRatios of XM17 to Gonal-f® for Cmax and AUC0-t equaled 1.017 (90 % confidence interval [CI]: 0.958, 1.080) and 1.028 (90 % CI: 0.931, 1.134), respectively, with the CIs contained within the predefined interval (0.8, 1.25). Ratios for AUC0-168h, AUC0-∞ and t1/2 were also ~1, and no difference in tmax was detected. Both XM17 and Gonal-f® were well tolerated, with no detectable anti-FSH antibodies, serious AEs or AEs leading to discontinuation or dose reduction.ConclusionsPK bioequivalence of single 300-IU sc doses of XM17 to the reference product Gonal-f® was statistically demonstrated. XM17 was well tolerated both systemically and locally.Trial registrationClinicalTrials.gov: NCT02592031; date of registration: 28 October, 2015.

【 授权许可】

CC BY   
© Lammerich et al. 2015

【 预 览 】
附件列表
Files Size Format View
RO202311108641163ZK.pdf 478KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  文献评价指标  
  下载次数:1次 浏览次数:1次