期刊论文详细信息
Journal of Translational Medicine
Comparison of hemostatic dressings for superficial wounds using a new spectrophotometric coagulation assay
Research
Matthias Fröhlich1  Marc Maegele1  Nadine Schäfer2  Julian-Dario Rembe2  Carolin Fromm-Dornieden2  Julia K. Böhm2  Ewa K. Stuermer2 
[1] Department of Traumatology, Orthopaedic Surgery and Sports Traumatology, Cologne-Merheim Medical Centre (CMMC), Witten/Herdecke University, Campus Cologne-Merheim, Ostmerheimer Str. 200, 51109, Cologne, Germany;Institute for Research in Operative Medicine (IFOM), Witten/Herdecke University, Ostmerheimer Str. 200, 51109, Cologne, Germany;
关键词: Superficial wound dressing;    Hemostasis;    Hemostatic agents;    Absorption;    Oral anticoagulation;   
DOI  :  10.1186/s12967-015-0740-5
 received in 2015-06-05, accepted in 2015-11-24,  发布年份 2015
来源: Springer
PDF
【 摘 要 】

BackgroundDue to demographical changes the number of elderly patients depending on oral anticoagulation is expected to rise. Prolonged bleeding times in case of traumatic injuries represent the drawback of these medications, not only in major trauma, but also in superficial wounds. Therefore, dressings capable of accelerating coagulation onset and shortening bleeding times are desirable for these patients.MethodsThe hemostatic potential and physical properties of different types of superficial wound dressings (standard wound pad, two alginates, chitosan, collagen (Lyostypt®), oxidized cellulose, and QuikClot®) were assessed in vitro. For this purpose the clotting times of blood under the influence of the named hemostatics from healthy volunteers were compared with Marcumar® or ASS® treated patients. For that, a newly developed coagulation assay based on spectrophotometric extinction measurements of thrombin activity was used.ResultsThe fastest coagulation onset was observed for oxidized cellulose (Ø 2.47 min), Lantor alginate-l (Ø 2.50 min) and QuikClot® (Ø 3.01 min). Chitosan (Ø 5.32 min) and the collagen Lyostypt® (Ø 7.59 min) induced clotting comparatively late. Regarding physical parameters, QuikClot® showed the lowest absorption capacity and speed while chitosan and both alginates achieved the highest. While oxidized cellulose displayed the best clotting times, unfortunately it also revealed low absorption capacity.ConclusionsAll tested specimens seem to induce clotting independently from the administered type of oral anticoagulant, providing the possibility to neglect the disadvantage in clotting times arising from anticoagulation on a local basis. QuikClot®, oxidized cellulose and unexpectedly alginate-l were superior to chitosan and Lyostypt®. Due to its additional well-known positive effect on wound healing alginate-l should be considered for further investigations.

【 授权许可】

CC BY   
© Rembe et al. 2015

【 预 览 】
附件列表
Files Size Format View
RO202311107747086ZK.pdf 1244KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  • [46]
  • [47]
  • [48]
  • [49]
  • [50]
  文献评价指标  
  下载次数:2次 浏览次数:0次