BMC Medical Imaging
Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty)
Research Article
Jiang Liu1  Beng H Lee1  Jun Cheng1  Hla M Htoon2  Melissa HY Wong3  Annabel Chew3  Donald T Tan4  Jodhbir S Mehta5 
[1] Institute for Infocomm Research (I2R), Infocomm, Singapore;Singapore Eye Research Institute (SERI), SERI, Singapore;Singapore National Eye Centre (SNEC), 11 Third Hospital Avenue, 168751, SNEC, Singapore;Singapore National Eye Centre (SNEC), 11 Third Hospital Avenue, 168751, SNEC, Singapore;Singapore Eye Research Institute (SERI), SERI, Singapore;Yong Loo Lin School of Medicine, National University of Singapore, Yong Loo Lin, Singapore;Singapore National Eye Centre (SNEC), 11 Third Hospital Avenue, 168751, SNEC, Singapore;Singapore Eye Research Institute (SERI), SERI, Singapore;Yong Loo Lin School of Medicine, National University of Singapore, Yong Loo Lin, Singapore;Department of Clinical Sciences, Duke-NUS Graduate Medical School, Duke-NUS, Singapore;
关键词: Anterior segment optical coherence tomography;    Descemet Stripping Automated Endothelial Keratoplasty;    Graft thickness;   
DOI  :  10.1186/1471-2342-12-25
 received in 2011-11-16, accepted in 2012-07-17,  发布年份 2012
来源: Springer
PDF
【 摘 要 】

BackgroundThe CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers.MethodsThis was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement.ResultsThere was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts.ConclusionThe analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.

【 授权许可】

Unknown   
© Wong et al.; licensee BioMed Central Ltd. 2012. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

【 预 览 】
附件列表
Files Size Format View
RO202311106104500ZK.pdf 917KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  文献评价指标  
  下载次数:0次 浏览次数:0次