BMC Medical Imaging
Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty)
Jodhbir S Mehta2  Donald T Tan4  Jiang Liu1  Jun Cheng1  Beng H Lee1  Hla M Htoon5  Annabel Chew3  Melissa HY Wong3 
[1] Institute for Infocomm Research (I2R), Infocomm, Singapore;Department of Clinical Sciences, Duke-NUS Graduate Medical School, Duke-NUS, Singapore;Singapore National Eye Centre (SNEC), 11 Third Hospital Avenue, 168751, SNEC, Singapore;Yong Loo Lin School of Medicine, National University of Singapore, Yong Loo Lin, Singapore;Singapore Eye Research Institute (SERI), SERI, Singapore
关键词: Graft thickness;    Descemet Stripping Automated Endothelial Keratoplasty;    Anterior segment optical coherence tomography;   
Others  :  1091819
DOI  :  10.1186/1471-2342-12-25
 received in 2011-11-16, accepted in 2012-07-17,  发布年份 2012
PDF
【 摘 要 】

Background

The CorneaL GrAft Thickness Evaluation (COLGATE) system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers.

Methods

This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC) independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement.

Results

There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962). Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963) and 0.967 (95% CI 0.942 to 0.981) for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969). The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949) and 0.968 (95% CI 0.945 to 0.982) for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003). The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts.

Conclusion

The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.

【 授权许可】

   
2012 Wong et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150128174521648.pdf 1355KB PDF download
Figure 2. 53KB Image download
Figure 1. 58KB Image download
【 图 表 】

Figure 1.

Figure 2.

【 参考文献 】
  • [1]Melles GR, Wijdh RH, Nieuwendaal CP: A technique to excise the descemet membrane from a recipient cornea (descemetorhexis). Cornea. 2004, 23:286-288.
  • [2]Li Y, Netto MV, Huang D, et al.: A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography. Ophthalmology 2007, 114:1124-1132.
  • [3]Wylegala E, Teper S, Dobrowolski D, et al.: Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 2009, 35:1410-1414.
  • [4]Leung CK, Weinreb RN: Anterior chamber angle imaging with optical coherence tomography. Eye 2011, 25:261-267.
  • [5]Lee BH, Mehta J, Wong TY, et al.: Cornea Graft Detection for Descemet’s Stripping Automated endothelial Keratoplasty using Optical Coherence Tomography. Conf Proc IEEE Eng Med Biol Soc 2010, 2010:3037-3040.
  • [6]Hall RC, Tan D, Mehta JS, et al.: J Cataract Refract Surg. 2011, 37:544-551.
  • [7]Canny J: A Computational Approach To Edge Detection. IEEE Trans. Pattern Analysis and Machine Intelligence 1986, 8(6):679-698.
  • [8]International Organization for Standardization: Accuracy (trueness and Precision) of Measurement Methods and Results. Part 1. Basic Methods for the Determination of Repeatability and Reproducibility of a Standard Measurement Method, Geneva, Switzerland, ISO; 1994:1-5725.
  • [9]International Organization for Standardization: Accuracy (trueness and Precision) of Measurement Methods and Results. Part 2. Basic Methods for the Determination of Repeatability and Reproducibility of a Standard Measurement Method, Geneva, Switzerland, ISO; 1994:2-5725.
  • [10]Sliverman RH: High-resolution ultrasound imaging of the eye – a review. Clin Experiment Ophthalmol 2009, 37:54-67.
  • [11]Holz HA, Mifflin M, Moshirfar M, et al.: Corneal profile analysis after Descemet stripping endothelial keratoplasty and its relationship to postoperative hyperopic shift. J Cataract Refract Surg 2008, 34:211-214.
  • [12]Nieuwendaal CP, Melles GR, Verbraak FD, et al.: Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography. Cornea 2009, 28:298-303.
  • [13]Shih CY, Liebmann JM, Ritch R, et al.: The use of postoperative slit-lamp optical coherence tomography to predict primary failure in descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 2009, 147:796-800.
  • [14]Scorcia V, Scorcia G, Busin M, et al.: Pentacam assessment of posterior lamellar grafts to explain hyperopization after Descemet's stripping automated endothelial keratoplasty. Am J Ophthalmol 2009, 147:796-800.
  • [15]Jun B, Carlson AN, Kim T, et al.: Refractive change after descemet stripping automated endothelial keratoplasty surgery and its correlation with graft thickness and diameter. Cornea 2009, 28:19-23.
  • [16]Yuen LH, Tan DT, Mehta JS, et al.: Biometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study. Invest Ophthalmol Vis Sci. 2010, 51:3433-3440.
  • [17]Narayanswamy A, Foster PJ, Aung T, et al.: Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 2010, 128:1321-1327.
  文献评价指标  
  下载次数:0次 浏览次数:9次