期刊论文详细信息
BMC Musculoskeletal Disorders
Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
Research
Sirgiovanni Mattia1  Malerba Giuseppe2  D’ Adamio Stefano3  Bonfiglio Nadia3  Ruberto Pasquale3  Maccauro Giulio3  Vitiello Raffaele3  De Santis Vincenzo3  Basilico Mattia3 
[1] Department of Medical Oncology and Pneumology, University Hospital Tuebingen, Tuebingen, Germany;Cluster of Excellence iFIT (EXC 2180) “Image-Guided and Functionally Instructed Tumor Therapies”, University of Tuebingen, Tuebingen, Germany;Fondazione Policlinico Universitario Agostino Gemelli – IRCCS, Largo Agostino Gemelli 8, 00168, Rome, Italy;Fondazione Policlinico Universitario Agostino Gemelli – IRCCS, Largo Agostino Gemelli 8, 00168, Rome, Italy;Università Cattolica Del Sacro Cuore, Roma, Italy;
关键词: Hip;    Replacement;    Ceramic;    Polyethylene;    Wear, outcomes;   
DOI  :  10.1186/s12891-021-04950-x
 received in 2021-12-08, accepted in 2021-12-09,  发布年份 2021
来源: Springer
PDF
【 摘 要 】

BackgroundNowadays hip replacement is one of the most successful surgery in terms of clinical outcome and patient’s satisfaction. Therefore, the choice of biomaterials in hip replacement is increasingly important with the aim of obtaining a long-term satisfaction of patient and a greater survivorship of the implants. Ceramic-on-polyethylene (COP) and ceramic-on-ceramic (CoC) bearings are two common coupling used in total hip arthroplasty. The aim of this retrospective study was to compare clinical and radiological outcomes between patients treated using CoC and CoP THA at a mean follow-up of 15 years.Methods86 patients, average age 65.6, were included in the study: 43 in group A bearing CoC and 43 in group B bearing CoP. Minimum follow-up was 13 years.Primary outcome was a clinical evaluation assessed by HOOS and SF-12 questionnaires.Secondary outcome was a radiological evaluation on a A-P pelvis x-ray calculating acetabular cup inclination and anteversion and detecting osteolysis.ResultAfter a multivariate analysis was performed, our results show clinical outcomes in group B significantly better than in group A: statistically significant value (p < 0,05) was found in the mean HOOS-symptoms subscale (83.0 ± 15.4 in Group A vs 90.3 ± 12.2 in group B) in the SF-12 physical component score (39.7 ± 11.0 in Group A vs 48.1 ± 10.1 in group B) and in HOOS (79.0 ± 16 in Group A vs 87.0 ± 16 in group B). 3 squeaking was found in group A. The calculated mean acetabular cup inclination value was 44,87 in group A and 44,5 in group B and the mean socket version was 17,54 in group A and 15,10 in group B. No significant statistically relationship between radiographic parameters analyzed and clinical outcomes was noted.ConclusionThe current results provide us important information about the THA long-term outcome. CoP offered significantly better results compared with CoC at long-term follow up, and thus it should be considered in the choose of bearing in THA.

【 授权许可】

CC BY   
© The Author(s) 2022

【 预 览 】
附件列表
Files Size Format View
RO202311105213000ZK.pdf 2546KB PDF download
Fig. 10 427KB Image download
Fig. 1 123KB Image download
Fig. 4 2368KB Image download
Fig. 4 183KB Image download
【 图 表 】

Fig. 4

Fig. 4

Fig. 1

Fig. 10

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  • [46]
  • [47]
  • [48]
  • [49]
  • [50]
  文献评价指标  
  下载次数:9次 浏览次数:2次