Easy to use and reliable technique for online dissolved oxygen tension measurement in shake flasks using infrared fluorescent oxygen-sensitive nanoparticles
Research
Tobias Ladner1  Mihaly Lukacs1  David Flitsch1  Jochen Büchs1 
[1] Biochemical Engineering, AVT-Aachener Verfahrenstechnik, RWTH Aachen University, Worringerweg 1, 52074, Aachen, Germany;
关键词: Online monitoring;    Dissolved oxygen tension;    Oxygen-sensitive nanoparticles;    Optical measurement;    Shake flask;    RAMOS;   
DOI  :  10.1186/s12934-016-0444-4
 received in 2015-12-17, accepted in 2016-02-15,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundDespite the progressive miniaturization of bioreactors for screening purposes, shake flasks are still widespread in biotechnological laboratories and industry as cultivation vessels. Shake flasks are often applied as the first or second step in applications such as strain screening or media optimization. Thus, there are ongoing efforts to develop online measurement techniques for shake flasks, to gain as much information as possible about the cultured microbial system. Since dissolved oxygen tension (DOT) is a key experimental parameter, its accurate determination during the course of experiment is critical. Some of the available DOT measurement techniques can lead to erroneous measurements or are very difficult to handle. A reliable and easy to use DOT measurement system, based on suspended oxygen-sensitive nanoparticles, is presented in this work.ResultsIn a cultivation of Kluyveromyces lactis, a new DOT measurement technique via suspended oxygen-sensitive nanoparticles was compared with the conventional DOT measurement via fixed sensor spots. These experiments revealed the main disadvantage of applying sensor spots. With further cultivations of Escherichia coli and Hansenula polymorpha, the new measurement technique was successfully validated. In combination with a RAMOS device, kLa values were determined during the presented cultivations. The determined kLa values are in good agreement with a correlation recently found in the literature.ConclusionsThe presented DOT measurement technique via suspended oxygen-sensitive nanoparticles in shake flasks turned out to be easy to use, robust and reliable under all applied combinations of shaking frequencies and filling volumes. Its applicability as an online monitoring system for cultivations was shown by means of four examples. Additionally, in combination with a RAMOS device, the possibility of experimental kLa determination was successfully demonstrated.

【 授权许可】

CC BY   
© Flitsch et al. 2016

【 预 览 】
附件列表
Files Size Format View
RO202311102826211ZK.pdf 2785KB PDF download
Fig. 10 1239KB Image download
Fig. 2 1305KB Image download
Fig. 1 1997KB Image download
12951_2017_255_Article_IEq39.gif 1KB Image download
Fig. 5 90KB Image download
12936_2016_1182_Article_IEq39.gif 1KB Image download
MediaObjects/12947_2023_317_MOESM1_ESM.docx 420KB Other download
Fig. 2 826KB Image download
Fig. 1 110KB Image download
MediaObjects/13046_2023_2862_MOESM6_ESM.png 301KB Other download
Fig. 1 344KB Image download
MediaObjects/41408_2023_930_MOESM3_ESM.docx 24KB Other download
MediaObjects/41408_2023_930_MOESM4_ESM.docx 22KB Other download
Fig. 11 260KB Image download
Fig. 1 294KB Image download
Fig. 16 216KB Image download
12888_2023_5206_Article_IEq1.gif 1KB Image download
Fig. 17 99KB Image download
12888_2023_5206_Article_IEq3.gif 1KB Image download
12951_2015_155_Article_IEq69.gif 1KB Image download
Fig. 1 410KB Image download
Fig. 1 801KB Image download
MediaObjects/40798_2023_647_MOESM1_ESM.docx 181KB Other download
12947_2017_100_Article_IEq1.gif 1KB Image download
Fig. 3 2497KB Image download
Fig. 4 603KB Image download
MediaObjects/12888_2023_5220_MOESM1_ESM.docx 69KB Other download
Fig. 8 474KB Image download
【 图 表 】

Fig. 8

Fig. 4

Fig. 3

12947_2017_100_Article_IEq1.gif

Fig. 1

Fig. 1

12951_2015_155_Article_IEq69.gif

12888_2023_5206_Article_IEq3.gif

Fig. 17

12888_2023_5206_Article_IEq1.gif

Fig. 16

Fig. 1

Fig. 11

Fig. 1

Fig. 1

Fig. 2

12936_2016_1182_Article_IEq39.gif

Fig. 5

12951_2017_255_Article_IEq39.gif

Fig. 1

Fig. 2

Fig. 10

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  文献评价指标  
  下载次数:13次 浏览次数:3次