期刊论文详细信息
BMC Gastroenterology
Faecal immunochemical test accuracy in patients referred for surveillance colonoscopy: a multi-centre cohort study
Research Article
Anneke A Bouman1  Veerle MH Coupé2  René WM van der Hulst3  Pieter Scholten4  Annekatrien CTM Depla5  Chris JJ Mulder6  Usha Coblijn6  Sietze T van Turenhout6  Frank A Oort6  Ruud Duijkers6  Lisette van der Eem6  Vincent A Steeman6  Jochim S Terhaar sive Droste7  Ruud JLF Loffeld8  Gerrit A Meijer9 
[1] Clinical Chemistry, VU University Medical Centre, Amsterdam, The Netherlands;Epidemiology and Biostatistics, VU University Medical Centre, Amsterdam, The Netherlands;Gastroenterology and Hepatology, Kennemer Gasthuis, Haarlem, The Netherlands;Gastroenterology and Hepatology, Sint Lucas Andreas Hospital, Amsterdam, The Netherlands;Gastroenterology and Hepatology, Slotervaart Hospital, Amsterdam, The Netherlands;Gastroenterology and Hepatology, VU University Medical Centre, Amsterdam, The Netherlands;Gastroenterology and Hepatology, VU University Medical Centre, Amsterdam, The Netherlands;Department of Gastroenterology and Hepatology, VU University Medical Centre, P.O. Box 7057, 1007, Amsterdam, MB, The Netherlands;Internal Medicine, Zaans Medical Centre, Zaandam, The Netherlands;Pathology, VU University Medical Centre, Amsterdam, The Netherlands;
关键词: Colorectal cancer;    Faecal immunochemical test (FIT);    Surveillance;    Advanced adenoma;    Sensitivity;   
DOI  :  10.1186/1471-230X-12-94
 received in 2012-01-10, accepted in 2012-07-24,  发布年份 2012
来源: Springer
PDF
【 摘 要 】

BackgroundGiven the increasing burden on colonoscopy capacity, it has been suggested that faecal immunochemical test (FIT) results could guide surveillance colonoscopy intervals. Against this background, we have evaluated the test accuracy of single and double FIT sampling to detect colorectal cancer (CRC) and/or advanced adenomas in an asymptomatic colonoscopy-controlled high-risk population.MethodsCohort study of asymptomatic high-risk patients (personal history of adenomas/CRC or family history of CRC), who provided one or two FITs before elective colonoscopy. Test accuracy of FIT for detection of CRC and advanced adenomas was determined (cut-off level 50 ng/ml).Results1,041 patients provided a FIT (516 personal history of adenomas, 172 personal history of CRC and 353 family history of CRC). Five CRCs (0.5%) and 101 advanced adenomas (9.7%) were detected by colonoscopy. Single FIT sampling resulted in a sensitivity, specificity, PPV and NPV for CRC of 80%, 89%, 3% and 99.9%, respectively, and for advanced adenoma of 28%, 91%, 24% and 92%, respectively. Double FIT sampling did not result in a significantly higher sensitivity for advanced neoplasia. Simulation of multiple screening rounds indicated that sensitivity of FIT for advanced adenoma could reach 81% after 5 screening rounds.ConclusionsIn once-only FIT sampling before surveillance colonoscopy, 70% of advanced neoplasia were missed. A simulation approach indicates that multiple screening rounds may be more promising in detecting advanced neoplasia and could potentially alleviate endoscopic burden.

【 授权许可】

CC BY   
© Terhaar sive Droste et al.; licensee BioMed Central Ltd. 2012

【 预 览 】
附件列表
Files Size Format View
RO202311101808348ZK.pdf 431KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  文献评价指标  
  下载次数:1次 浏览次数:0次