BMC Ophthalmology | |
Short-term reproducibility of intraocular pressure and ocular perfusion pressure measurements in Chinese volunteers and glaucoma patients | |
Research Article | |
Bing Wan1  Peiyu Li2  Yan Zhang3  Xin Tang3  Yanlin Gao3  | |
[1] Department of Laboratory, Central Hospital Affiliated to Shenyang Medical College, Shenyang, China;Department of Ophthalmology, the Second Hospital Affiliated to Dalian Medical University, Dalian, China;Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Vision Science, Clinical College of Ophthalmology, Tianjin Medical University, 4, Gansu Road, Heping District, 300020, Tianjin, People’s Republic of China; | |
关键词: Glaucoma; Glaucoma Patient; Central Corneal Thickness; Excellent Reproducibility; POAG Patient; | |
DOI : 10.1186/s12886-016-0323-0 | |
received in 2016-01-24, accepted in 2016-06-16, 发布年份 2016 | |
来源: Springer | |
【 摘 要 】
BackgroundTo evaluate the short-term reproducibility of diurnal intraocular pressure (IOP) and ocular perfusion pressure (OPP) measurements in normal volunteers, untreated normal-tension glaucoma (NTG) and primary open-angle glaucoma (POAG) patients.MethodsFifty-four healthy volunteers (control group), 67 NTG patients and 54 POAG patients were recruited. The IOPs of both eyes were measured with a Goldmann applanation tonometer at 3-h intervals over 2 consecutive days. Blood pressure (BP) measurements were collected at the same times. The mean IOP/OPP, peak IOP/OPP, trough IOP/OPP and IOP/OPP fluctuations on each day were also calculated. The intraclass correlation coefficients (ICCs) were used to evaluate the reproducibilities.ResultsIn the control group, the ICCs of mean IOP, peak IOP, trough IOP and IOP fluctuation were 0.921, 0.889, 0.888, and 0.661, respectively, and the ICCs of the mean OPP, peak OPP, trough OPP and OPP fluctuations were 0.962, 0.918, 0.953, and 0.680, respectively. In the NTG group, the ICCs of the mean IOP, peak IOP, trough IOP and IOP fluctuation were 0.862, 0.741, 0.798, and 0.290, respectively, and the ICCs of the mean OPP, peak OPP, trough OPP and OPP fluctuations were 0.947, 0.828, 0.927, and −0.008, respectively. In the POAG group, the ICCs of the mean IOP, peak IOP, trough IOP and IOP fluctuation were 0.857, 0.666, 0.808, and 0.546, respectively, and the ICCs of the mean OPP, peak OPP, trough OPP and OPP fluctuation were 0.934, 0.842, 0.910, and 0.093, respectively.ConclusionThe IOP measurements within a single day were not highly reproducible in the short-term. The normal volunteers exhibited better IOP and OPP reproducibilities than the glaucoma patients. The IOP and OPP fluctuations could not be accurately evaluated based on the IOP or OPP measurements within a single day.
【 授权许可】
CC BY
© The Author(s). 2016
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311098708742ZK.pdf | 733KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]