期刊论文详细信息
BMC Medical Informatics and Decision Making
Substance deposition assessment in obstructed pulmonary system through numerical characterization of airflow and inhaled particles attributes
Research
Konstantinos Moustakas1  Stavros Nousias1  Aris Lalos1  Gerasimos Arvanitis1  Dimitrios Tzovaras2  Antonios Lalas2  Christos Sougles2  Konstantinos Votis2  Dimitrios Kikidis2  Omar Usmani3  Sylvia Verbanck4 
[1] Department of Electrical and Computer Engineering, University of Patras, Patra, Greece;Information Technologies Institute, Centre for Research and Technology - Hellas (CERTH), Thessaloniki, Greece;National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, London, UK;Respiratory Division, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium;
关键词: Computational fluid dynamics;    Fluid particle tracing;    Obstructive lung diseases;    Aerosol deposition;    Human airways;   
DOI  :  10.1186/s12911-017-0561-y
来源: Springer
PDF
【 摘 要 】

BackgroundChronic obstructive pulmonary disease (COPD) and asthma are considered as the two most widespread obstructive lung diseases, whereas they affect more than 500 million people worldwide. Unfortunately, the requirement for detailed geometric models of the lungs in combination with the increased computational resources needed for the simulation of the breathing did not allow great progress to be made in the past for the better understanding of inflammatory diseases of the airways through detailed modelling approaches. In this context, computational fluid dynamics (CFD) simulations accompanied by fluid particle tracing (FPT) analysis of the inhaled ambient particles are deemed critical for lung function assessment. Also they enable the understanding of particle depositions on the airways of patients, since these accumulations may affect or lead to inflammations. In this direction, the current study conducts an initial investigation for the better comprehension of particle deposition within the lungs. More specifically, accurate models of the airways obstructions that relate to pulmonary disease are developed and a thorough assessment of the airflow behavior together with identification of the effects of inhaled particle properties, such as size and density, is conducted. Our approach presents a first step towards an effective personalization of pulmonary treatment in regards to the geometric characteristics of the lungs and the in depth understanding of airflows within the airways.MethodsA geometry processing technique involving contraction algorithms is established and used to employ the different respiratory arrangements associated with lung related diseases that exhibit airways obstructions. Apart from the normal lung case, two categories of obstructed cases are examined, i.e. models with obstructions in both lungs and models with narrowings in the right lung only. Precise assumptions regarding airflow and deposition fraction (DF) over various sections of the lungs are drawn by simulating these distinct incidents through the finite volume method (FVM) and particularly the CFD and FPT algorithms. Moreover, a detailed parametric analysis clarifies the effects of the particles size and density in terms of regional deposition upon several parts of the pulmonary system. In this manner, the deposition pattern of various substances can be assessed.ResultsFor the specific case of the unobstructed lung model most particles are detected on the right lung (48.56% of total, when the air flowrate is 12.6 L/min), a fact that is also true when obstructions arise symmetrically in both lungs (51.45% of total, when the air flowrate is 6.06 L/min and obstructions occur after the second generation). In contrast, when narrowings are developed on the right lung only, most particles are pushed on the left section (68.22% of total, when the air flowrate is 11.2 L/min) indicating that inhaled medication is generally deposited away from the areas of inflammation. This observation is useful when designing medical treatment of lung diseases. Furthermore, particles with diameters from 1 μm to 10 μm are shown to be mainly deposited on the lower airways, whereas particles with diameters of 20 μm and 30 μm are mostly accumulated in the upper airways. As a result, the current analysis indicates increased DF levels in the upper airways when the particle diameter is enlarged. Additionally, when the particles density increases from 1000 Kg/m3 to 2000 Kg/m3, the DF is enhanced on every generation and for all cases investigated herein. The results obtained by our simulations provide an accurate and quantitative estimation of all important parameters involved in lung modeling.ConclusionsThe treatment of respiratory diseases with inhaled medical substances can be advanced by the clinical use of accurate CFD and FPT simulations and specifically by evaluating the deposition of inhaled particles in a regional oriented perspective in regards to different particle sizes and particle densities. Since a drug with specific characteristics (i.e. particle size and density) exhibits maximum deposition on particular lung areas, the current study provides initial indications to a qualified physician for proper selection of medication.

【 授权许可】

CC BY   
© The Author(s). 2017

【 预 览 】
附件列表
Files Size Format View
RO202311094284889ZK.pdf 5833KB PDF download
12902_2017_191_Article_IEq3.gif 1KB Image download
12888_2016_877_Article_IEq4.gif 1KB Image download
12864_2015_2192_Article_IEq10.gif 1KB Image download
12864_2017_4228_Article_IEq1.gif 1KB Image download
12864_2017_4228_Article_IEq2.gif 1KB Image download
12864_2017_3715_Article_IEq1.gif 1KB Image download
12864_2017_4132_Article_IEq12.gif 1KB Image download
12864_2017_3916_Article_IEq1.gif 1KB Image download
12864_2015_2174_Article_IEq1.gif 1KB Image download
12864_2017_4133_Article_IEq3.gif 1KB Image download
12864_2015_2192_Article_IEq19.gif 1KB Image download
12864_2017_4132_Article_IEq18.gif 1KB Image download
12888_2016_877_Article_IEq23.gif 1KB Image download
12888_2016_877_Article_IEq24.gif 1KB Image download
12864_2017_4071_Article_IEq2.gif 1KB Image download
12864_2017_4071_Article_IEq3.gif 1KB Image download
12864_2017_3920_Article_IEq1.gif 1KB Image download
12864_2015_2304_Article_IEq10.gif 1KB Image download
12864_2015_2129_Article_IEq18.gif 1KB Image download
【 图 表 】

12864_2015_2129_Article_IEq18.gif

12864_2015_2304_Article_IEq10.gif

12864_2017_3920_Article_IEq1.gif

12864_2017_4071_Article_IEq3.gif

12864_2017_4071_Article_IEq2.gif

12888_2016_877_Article_IEq24.gif

12888_2016_877_Article_IEq23.gif

12864_2017_4132_Article_IEq18.gif

12864_2015_2192_Article_IEq19.gif

12864_2017_4133_Article_IEq3.gif

12864_2015_2174_Article_IEq1.gif

12864_2017_3916_Article_IEq1.gif

12864_2017_4132_Article_IEq12.gif

12864_2017_3715_Article_IEq1.gif

12864_2017_4228_Article_IEq2.gif

12864_2017_4228_Article_IEq1.gif

12864_2015_2192_Article_IEq10.gif

12888_2016_877_Article_IEq4.gif

12902_2017_191_Article_IEq3.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  文献评价指标  
  下载次数:0次 浏览次数:2次