BMC Musculoskeletal Disorders | |
Inter-rater reliability of clinical mobility measures in ankylosing spondylitis | |
Research Article | |
J. Calvo-Gutiérrez1  M. C. Castro-Villegas1  J. L. Garrido-Castro1  R. Ortega-Castro1  A. Escudero-Contreras1  C. López-Medina1  E. Collantes-Estévez1  C. González-Navas1  P. Font-Ugalde1  | |
[1] Rheumatology Department, Reina Sofía University Hospital, Maimonides Institute for Biomedical Research of Cordoba (IMIBIC), University of Cordoba, Av/ Menedez Pidal SN, 14001, Cordoba, Spain; | |
关键词: Ankylosing spondylitis; Reliability; Reproducibility; Smallest detectable difference; BASMI; | |
DOI : 10.1186/s12891-016-1242-1 | |
received in 2016-02-03, accepted in 2016-09-02, 发布年份 2016 | |
来源: Springer | |
【 摘 要 】
BackgroundSeveral measurements are often used in daily clinical practice in the assessment of Ankylosing Spondylitis (AS) patients. The Assessment in SpondyloArthiritis International Society (ASAS) recommend in its core set: chest expansion modified Schöber test, Occiput to wall distance, lateral lumbar flexion, cervical rotation and The Bath Ankylosing Spondylitis Metrology Index (BASMI). BASMI also includes five measurements, some of them recommended by ASAS. Three versions of BASMI have been published with different scales and intervals for each component of the index. Though studies about reliability of these measurements are needed. The aim of this study was to analyze inter-rater reliability of recommended spinal mobility measures in AS.MethodsWe examined reproducibility of spinal mobility measurements on 33 AS patients performed by two experienced rheumatologists in the same day. Descriptive statistics, Intraclass Correlation Coefficients (ICC), and Smallest Detectable Difference (SDD) using the Bland-Altman criteria were obtained for all the measurements.ResultsChest expansion showed the lowest value of ICC (0.66) and occiput-wall the highest (0.97). SDD was 2.43 units for BASMI2 and 1.27 units for BASMI10.ConclusionsReliability according to ICC was moderate to high in all measurements. BASMI10, instead BASMI2, must be used: measurements used to calculate are the same but there is better reliability. Inter-rater variation, expressed as SDD, must be taken in account: smaller improvements do not demonstrate the efficacy of treatment because they can be due to experimental error and not to the treatment itself.
【 授权许可】
CC BY
© The Author(s). 2016
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311094216123ZK.pdf | 462KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]