| BMC Cardiovascular Disorders | |
| Assessment of central haemomodynamics from a brachial cuff in a community setting | |
| Research Article | |
| Bernhard Hametner1  Siegfried Wassertheurer1  Carl Heneghan2  Alison Ward2  Daniel Lasserson2  David Nunan2  Susannah Fleming2  | |
| [1] AIT Austrian Institute of Technology GmbH, Donau-City-Straße 1, 1220, Vienna, Austria;Department of Primary Care Health Sciences, University of Oxford, Hythe Bridge St, Oxford, UK; | |
| 关键词: Central pressure; Augmentation; Hypertension; Primary care; Validation; | |
| DOI : 10.1186/1471-2261-12-48 | |
| received in 2011-12-14, accepted in 2012-06-15, 发布年份 2012 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundLarge artery stiffening and wave reflections are independent predictors of adverse events. To date, their assessment has been limited to specialised techniques and settings. A new, more practical method allowing assessment of central blood pressure from waveforms recorded using a conventional automated oscillometric monitor has recently been validated in laboratory settings. However, the feasibility of this method in a community based setting has not been assessed.MethodsOne-off peripheral and central haemodynamic (systolic and diastolic blood pressure (BP) and pulse pressure) and wave reflection parameters (augmentation pressure (AP) and index, AIx) were obtained from 1,903 volunteers in an Austrian community setting using a transfer-function like method (ARCSolver algorithm) and from waveforms recorded with a regular oscillometric cuff. We assessed these parameters for known differences and associations according to gender and age deciles from <30 years to >80 years in the whole population and a subset with a systolic BP < 140 mmHg.ResultsWe obtained 1,793 measures of peripheral and central BP, PP and augmentation parameters. Age and gender associations with central haemodynamic and augmentation parameters reflected those previously established from reference standard non-invasive techniques under specialised settings. Findings were the same for patients with a systolic BP below 140 mmHg (i.e. normotensive). Lower values for AIx in the current study are possibly due to differences in sampling rates, detection frequency and/or averaging procedures and to lower numbers of volunteers in younger age groups.ConclusionA novel transfer-function like algorithm, using brachial cuff-based waveform recordings, provides robust and feasible estimates of central systolic pressure and augmentation in community-based settings.
【 授权许可】
CC BY
© Nunan et al.; licensee BioMed Central Ltd. 2012
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202311091928737ZK.pdf | 760KB |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
PDF