Polydopamine (PDA) coatings with endothelial vascular growth factor (VEGF) immobilization inhibiting neointimal formation post zinc (zn) wire implantation in rat aortas
Research Article
Jiayin Fu1  Meng Zhao1  Jing Zhao1  Wenbin Zhang1  Shihui Xu1  Qiongjun Zhu1  Dongwu Lai1  Guosheng Fu1  Zhezhe Chen1  Shaofei Wu1 
[1] Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Department of Cardiology, Sir Run Run Shaw Hospital, Zhejiang University, 310016, Hangzhou, China;
关键词: Polydopamine (PDA);    Endothelial vascular growth factor (VEGF);    Neointimal formation;    Zinc (zn);    Degradation;   
DOI  :  10.1186/s40824-023-00423-5
 received in 2023-06-14, accepted in 2023-08-24,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundBioresorbable stents are designed to provide temporary mechanical support to the coronary arteries and then slowly degrade in vivo to avoid chronic inflammation. Zinc (Zn) is a promising material for bioresorbable stents; However, it can cause inflammation and neointimal formation after being implanted into blood vessels.MethodsTo improve biocompatibility of Zn, we first coated it with polydopamine (PDA), followed by immobilization of endothelial vascular growth factor (VEGF) onto the PDA coatings. Adhesion, proliferation, and phenotype maintenance of endothelial cells (ECs) on the coated Zn were evaluated in vitro. Then, a wire aortic implantation model in rats mimicking endovascular stent implantation in humans was used to assess vascular responses to the coated Zn wires in vivo. Thrombosis in aortas post Zn wire implantation, degradation of Zn wires in vivo, neointimal formation surrounding Zn wires, and macrophage infiltration and extracellular matrix (ECM) remodeling in the neointimas were examined.ResultsIn vitro data showed that the PDA-coated Zn encouraged EC adhesion, spreading, proliferation, and phenotype maintenance on its surfaces. VEGF functionalization on PDA coatings further enhanced the biocompatibility of Zn to ECs. Implantation of PDA-coated Zn wires into rat aortas didn’t cause thrombosis and showed a faster blood flow than pure Zn or the Zn wires coated with VEGF alone. In addition, the PDA coating didn’t affect the degradation of Zn wires in vivo. Besides, the PDA-coated Zn wires reduced neointimal formation, increased EC coverage, decreased macrophage infiltration, and declined aggrecan accumulation in ECM. VEGF immobilization onto PDA coatings didn’t cause thrombosis and affect Zn degradation in vivo as well, and further increased the endothelization percentage as compared to PDA coating alone, thus resulting in thinner neointimas.ConclusionThese results indicate that PDA coatings with VEGF immobilization would be a promising approach to functionalize Zn surfaces to increase biocompatibility, reduce inflammation, and inhibit neointimal formation after Zn implantation in vivo.Graphical Abstract

【 授权许可】

CC BY   
© The Korean Society for Biomaterials 2023

【 预 览 】
附件列表
Files Size Format View
RO202310119269245ZK.pdf 9674KB PDF download
13690_2023_1177_Fige_HTML.png 10KB Image download
12888_2023_5172_Article_IEq50.gif 1KB Image download
Fig. 2 90KB Image download
Fig. 2 645KB Image download
13731_2023_332_Article_IEq7.gif 1KB Image download
13690_2023_1170_Article_IEq148.gif 1KB Image download
MediaObjects/41408_2023_922_MOESM3_ESM.pptx 50KB Other download
Fig. 1 540KB Image download
Fig. 2 622KB Image download
Fig. 4 1878KB Image download
Fig. 4 747KB Image download
【 图 表 】

Fig. 4

Fig. 4

Fig. 2

Fig. 1

13690_2023_1170_Article_IEq148.gif

13731_2023_332_Article_IEq7.gif

Fig. 2

Fig. 2

12888_2023_5172_Article_IEq50.gif

13690_2023_1177_Fige_HTML.png

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  文献评价指标  
  下载次数:31次 浏览次数:2次