Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty
Research
Runhong Mei1  Shui Xiong2  Gaorong Deng2  Rongji Lin2  Binghua Wu2  Xuefeng Liu2  Zhipeng Li2  Wei Zheng2 
[1] Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital, Nanchang University, 330006, Nanchang, China;Department of Orthopaedics, The Fourth Affiliated Hospital, Nanchang University, 330003, Nanchang, China;
关键词: Patient-specific instrument;    Femoral anteversion;    Total hip arthroplasty;    3D printing;    Surgical guide;   
DOI  :  10.1186/s12938-023-01152-5
 received in 2023-03-27, accepted in 2023-08-31,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundThe aim of this study was to evaluate the precision and feasibility of patient-specific instruments (PSI) in total hip arthroplasty (THA) as compared to the traditional free-hand (FRH) approach.MethodsDuring the period of January 1, 2021 to December 31, 2022, a randomized allocation was used for patients receiving unilateral primary THA to either the PSI or conventional operation group. The placement and size of the PSI were specifically chosen to guide femoral neck resection and prosthesis implantation. The study analyzed component positions and evaluated radiographic and clinical outcomes in 30 patients who received PSI-assisted THAs and 30 patients who received FRH THAs. This study was registered at China Clinical Trial Registry (number: ChiCTR2300072325) on June 9th, 2023.ResultsThe use of PSI in THA resulted in significantly higher precision in achieving the desired component position as compared to the FRH approach. The PSI group showed significantly smaller absolute errors of femoral anteversion (p < 0.001). No significant differences were found in operation time, intra-operative blood loss, hospitalization duration, or time to walk after surgery.ConclusionIn conclusion, the application of patient-specific instruments in THA provides a simple and reliable solution to enhance the precision of femoral prosthesis placement with high accuracy and feasibility. This study highlights the potential benefits of using the PSI in THA.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202310111131555ZK.pdf 1515KB PDF download
Fig. 4 988KB Image download
12951_2023_2095_Article_IEq6.gif 1KB Image download
MediaObjects/42004_2023_1007_MOESM1_ESM.pdf 3331KB PDF download
Fig. 4 567KB Image download
Fig. 14 1554KB Image download
13690_2023_1170_Article_IEq72.gif 1KB Image download
Fig.3 304KB Image download
【 图 表 】

Fig.3

13690_2023_1170_Article_IEq72.gif

Fig. 14

Fig. 4

12951_2023_2095_Article_IEq6.gif

Fig. 4

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  文献评价指标  
  下载次数:23次 浏览次数:0次