A customized anthropomorphic 3D-printed phantom to reproducibility assessment in computed tomography: an oncological case study
Oncology
Dario Baldi1  Carlo Cavaliere1  Valentina Brancato1  Marco Aiello1  Marco Salvatore1 
[1] IRCCS Synlab SDN, Naples, Italy;
关键词: 3D printing;    computed tomography;    phantom;    lung tumor;    polylactic acid;   
DOI  :  10.3389/fonc.2023.1123796
 received in 2022-12-14, accepted in 2023-08-07,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

IntroductionStudies on computed tomography (CT) reproducibility at different acquisition parameters have to take into account radiation dose administered and related ethical issues. 3D-printed phantoms provide the possibility to investigate these features deeply and to foster CT research, also taking advantage by outperforming new generation scanners. The aim of this study is to propose a new anthropomorphic 3D-printed phantom for chest lesions, tailored on a real patient CT scan, to investigate the variability of volume and Hounsfield Unit (HU) measurements at different CT acquisition parameters.MethodsThe chest CT of a 75-year-old patient with a paramediastinal lung lesion was segmented based on an eight-compartment approach related to HU ranges (air lung, lung interstitium, fat, muscle, vascular, skin, bone, and lesion). From each mask produced, the 3D.stl model was exported and linked to a different printing infill value, based on a preliminary test and HU ratios derived from the patient scan. Fused deposition modeling (FDM) technology printing was chosen with filament materials in polylactic acid (PLA). Phantom was acquired at 50 mAs and three different tube voltages of 80, 100, and 120 kVp on two different scanners, namely, Siemens Somatom Force (Siemens Healthineers, Erlangen, Germany; same setting of real patient for 80 kVp acquisition) and GE 750 HD CT (GE Healthcare, Chicago, IL). The same segmentation workflow was then applied on each phantom acquisition after coregistration pipeline, and Dice Similarity Coefficient (DSC) and HU averages were extracted and compared for each compartment.ResultsDSC comparison among real patient versus phantom scans at different kVp, and on both CT scanners, demonstrated a good overlap of different compartments and lesion vascularization with a higher similarity for lung and lesion masks for each setting (about 0.9 and 0.8, respectively). Although mean HU was not comparable with real data, due to the PLA material, the proportion of intensity values for each compartment remains respected.DiscussionThe proposed approach demonstrated the reliability of 3D-printed technology for personalized approaches in CT research, opening to the application of the same workflow to other oncological fields.

【 授权许可】

Unknown   
Copyright © 2023 Cavaliere, Baldi, Brancato, Aiello and Salvatore

【 预 览 】
附件列表
Files Size Format View
RO202310104323649ZK.pdf 6329KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:1次