期刊论文详细信息
Saudi Endodontic Journal
Effect of various volume syringes on solution delivery time using conventional irrigation technique in 0.04 tapered preparations of single straight root canals: An ex vivo study
article
Kavalipurapu Venkata Teja1  Sindhu Ramesh1  Sahil Choudhari1  Olcay Özdemir2  Krishnamachari Janani3  Jerry Jose1  Kaligotla Apoorva Vasundhara4  Gopi Battineni1 
[1] Departments of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University;Department of Endodontics, Faculty of Dentistry, Karabük University;Department of Conservative Dentistry and Endodontics, SRM Dental College, SRM Institute of Science and Technology;Department of Prosthodontist and Oral Implantologist
关键词: Endodontics;    irrigant;    root canal preparation;    rotary instrumentation;    syringe needle;   
DOI  :  10.4103/sej.sej_15_22
学科分类:口腔科学
来源: Medknow
PDF
【 摘 要 】

Introduction: The important aspect of endodontic treatment is root canal irrigation. Although agitation systems proved to have enhanced irrigant wall interactions, syringe needle-based delivery systems still play a significant role during the preparatory phases of root canal treatment. The current study aimed to evaluate the time taken for the irrigant delivery during conventional syringe irrigation using different volume syringes in different root canal preparations. Materials and Methods: Two hundred extracted single-rooted premolars with approximately round canals were randomly instrumented to preferred apical preparation sizes using 0.4 tapered Hyflex-CM rotary Ni-Ti instruments and randomly divided as follows: Group I, instrumentation to size 40, 0.04 taper (n = 50); Group II, instrumentation to size 30, 0.04 taper (n = 50); Group III, instrumentation to size 25, 0.04 taper (n = 50); and Group IV, instrumentation to size 20, 0.04 taper (n = 50). Fifty operators were chosen for the experimentation. They were asked to irrigate the prepared specimens using different volume syringes. The entire irrigant delivery time was recorded by a head nurse using a stopwatch, and the values were calibrated and statistically analyzed. Results: Group I recorded significantly lesser time for irrigant delivery during manual syringe needle irrigation (P = 0.005) compared to other groups. Conclusion: Irrigation delivery time was less in 40/0.04 taper preparations, using 1 ml volume syringes.

【 授权许可】

CC BY-NC-SA   

【 预 览 】
附件列表
Files Size Format View
RO202307100000930ZK.pdf 873KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:3次