期刊论文详细信息
IEICE Electronics Express
A continuous time level-crossing ADC with adaptive sampling for biomedical application
article
Rongshan Wei1  Fangjun Lin1  Qunchao Chen1 
[1] College of Physics and Information Engineering, Fuzhou University
关键词: analog-to-digital converter;    level-crossing;    adaptive sampling;   
DOI  :  10.1587/elex.19.20220072
学科分类:电子、光学、磁材料
来源: Denshi Jouhou Tsuushin Gakkai
PDF
【 摘 要 】

To reduce the power consumption of a bio-electrical signal detection system, a level-crossing analog-to-digital converter (LC-ADC) with low power consumption was proposed for biomedical signal detection. An adaptive resolution sampling mode is also designed to reduce power consumption on the original basis. The level-crossing ADC is designed and simulated using a 180-nm CMOS process. The measurement results show that the power consumption is only 197nW, the effective number of bits is 6.4 bits and the signal-to-noise and distortion ratio is 41.6dB under 0.8V power supply voltage. The proposed LC-ADC uses a chip area of 0.147mm2 and the FOM is 278fJ/conversion.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202306290004421ZK.pdf 3055KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:4次