| Detection of spin pumping from YIG by spin-charge conversion in a Au/Ni80Fe20 spin-valve structure | |
| Article | |
| 关键词: MAGNETIC INSULATOR; ROOM-TEMPERATURE; MAGNETORESISTANCE; ACCUMULATION; INJECTION; METAL; | |
| DOI : 10.1103/PhysRevB.94.035407 | |
| 来源: SCIE | |
【 摘 要 】
Many experiments have shown the detection of spin currents driven by radio-frequency spin pumping from yttrium iron garnet (YIG), by making use of the inverse spin-Hall effect, which is present in materials with strong spin-orbit coupling, such as Pt. Here we show that it is also possible to directly detect the resonance-driven spin current using Au| permalloy (Py, Ni80Fe20) devices, where Py is used as a detector for the spins pumped across a YIG| Au interface. This detection mechanism is equivalent to the spin-current detection in metallic nonlocal spin-valve devices. By finite element modeling we compare the pumped spin current from a reference Pt strip with the detected signals from the Au| Py devices. We find that for one series of Au| Py devices the calculated spin pumping signals mostly match the measurements, within 20%, whereas for a second series of devices additional signals are present which are up to a factor 10 higher than the calculated signals from spin pumping. We also identify contributions from thermoelectric effects caused by the resonant (spin-related) and nonresonant heating of theYIG. Thermocouples are used to investigate the presence of these thermal effects and to quantify the magnitude of the spin-(dependent-) Seebeck effect. Several additional features are observed, which are also discussed.
【 授权许可】
Free