期刊论文详细信息
Cardiovascular Ultrasound 卷:21
Global longitudinal strain assessment in contrast-enhanced echocardiography in breast cancer patients: a feasibility study
Research
Mei Liu1  Shichu Liang1  Zhuoqin Tang1  Zhiyue Liu1  Yupei Qin1  Xi Wang1  Qian Li1  He Huang1  Ting Liang1  Xiaorong Zhong2 
[1] Department of Cardiology, West China Hospital, Sichuan University, No.37 GuoXue Alley, 610041, Chengdu, China;
[2] Department of Head and Neck Oncology Cancer Center, West China Hospital, Sichuan University, 610041, Chengdu, China;Clinical Research Center for Breast, West China Hospital, Sichuan University, 610041, Chengdu, China;
关键词: Breast cancer;    Left ventricular global longitudinal strain;    Two-dimensional speckle-tracking echocardiography;    Contrast-enhanced echocardiography;    Autostrain;   
DOI  :  10.1186/s12947-023-00304-w
 received in 2022-12-04, accepted in 2023-04-02,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundLeft ventricular global longitudinal strain (GLS) obtained from two-dimensional speckle-tracking echocardiography (2D-STE) can reflect cancer therapy-related cardiac dysfunction in breast cancer (BC) patients, however, the accuracy and reproducibility of 2D-STE are restricted due to poor image quality.MethodsBetween January 2019 and October 2021, 160 consecutive BC patients aged ≥ 18 years were recruited. The 160 BC patients (mean age: 48.41 ± 9.93 years, 100% women) underwent both 2D-STE and Contrast-enhanced echocardiography (CEcho), 125 of whom were included in the measurement of GLS. The intraclass correlation coefficient (ICC) was used to determine the intra- and inter-observer reproducibility of 2D-STE and CEcho-STE. Correlation (r) was calculated using Pearson correlation. Statistical significance was set at P < 0.05.ResultsAmong 160 BC patients, more segments were recognized by CEcho-STE than by 2D-STE (2,771, 99.53% vs. 2,440, 84.72%). The left ventricular ejection fraction (LVEF) obtained by 2D was lower than CEcho (61.75 ± 6.59% vs. 64.14 ± 5.97%, P < 0.0001). The GLS obtained by 2D-STE was lower than CEcho-STE (-21.74 ± 2.77% vs. -26.79 ± 4.30%, P = 0.001). The ICC of the intraobserver and interobserver agreements in the CEcho-STE group was lower than that in the 2D-STE group. GLS measurements were in good agreement between the 2D-STE and CEcho-STE groups (r = 0.773).ConclusionsCEcho can overcome some imaging limitations and recognize more segments than 2D, which may provide an LVEF and GLS closer to the true value. Based on AutoStrain, CEcho-STE may serve as a complementary method for those with poor image quality.Graphical Abstract

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202304226595405ZK.pdf 2304KB PDF download
615KB Image download
Fig. 1 615KB Image download
Fig. 2 417KB Image download
Fig. 1 878KB Image download
Fig. 4 62KB Image download
【 图 表 】

Fig. 4

Fig. 1

Fig. 2

Fig. 1

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  文献评价指标  
  下载次数:74次 浏览次数:4次