Cardiovascular Ultrasound | 卷:21 |
Global longitudinal strain assessment in contrast-enhanced echocardiography in breast cancer patients: a feasibility study | |
Research | |
Mei Liu1  Shichu Liang1  Zhuoqin Tang1  Zhiyue Liu1  Yupei Qin1  Xi Wang1  Qian Li1  He Huang1  Ting Liang1  Xiaorong Zhong2  | |
[1] Department of Cardiology, West China Hospital, Sichuan University, No.37 GuoXue Alley, 610041, Chengdu, China; | |
[2] Department of Head and Neck Oncology Cancer Center, West China Hospital, Sichuan University, 610041, Chengdu, China;Clinical Research Center for Breast, West China Hospital, Sichuan University, 610041, Chengdu, China; | |
关键词: Breast cancer; Left ventricular global longitudinal strain; Two-dimensional speckle-tracking echocardiography; Contrast-enhanced echocardiography; Autostrain; | |
DOI : 10.1186/s12947-023-00304-w | |
received in 2022-12-04, accepted in 2023-04-02, 发布年份 2023 | |
来源: Springer | |
【 摘 要 】
BackgroundLeft ventricular global longitudinal strain (GLS) obtained from two-dimensional speckle-tracking echocardiography (2D-STE) can reflect cancer therapy-related cardiac dysfunction in breast cancer (BC) patients, however, the accuracy and reproducibility of 2D-STE are restricted due to poor image quality.MethodsBetween January 2019 and October 2021, 160 consecutive BC patients aged ≥ 18 years were recruited. The 160 BC patients (mean age: 48.41 ± 9.93 years, 100% women) underwent both 2D-STE and Contrast-enhanced echocardiography (CEcho), 125 of whom were included in the measurement of GLS. The intraclass correlation coefficient (ICC) was used to determine the intra- and inter-observer reproducibility of 2D-STE and CEcho-STE. Correlation (r) was calculated using Pearson correlation. Statistical significance was set at P < 0.05.ResultsAmong 160 BC patients, more segments were recognized by CEcho-STE than by 2D-STE (2,771, 99.53% vs. 2,440, 84.72%). The left ventricular ejection fraction (LVEF) obtained by 2D was lower than CEcho (61.75 ± 6.59% vs. 64.14 ± 5.97%, P < 0.0001). The GLS obtained by 2D-STE was lower than CEcho-STE (-21.74 ± 2.77% vs. -26.79 ± 4.30%, P = 0.001). The ICC of the intraobserver and interobserver agreements in the CEcho-STE group was lower than that in the 2D-STE group. GLS measurements were in good agreement between the 2D-STE and CEcho-STE groups (r = 0.773).ConclusionsCEcho can overcome some imaging limitations and recognize more segments than 2D, which may provide an LVEF and GLS closer to the true value. Based on AutoStrain, CEcho-STE may serve as a complementary method for those with poor image quality.Graphical Abstract
【 授权许可】
CC BY
© The Author(s) 2023
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202304226595405ZK.pdf | 2304KB | download | |
615KB | Image | download | |
Fig. 1 | 615KB | Image | download |
Fig. 2 | 417KB | Image | download |
Fig. 1 | 878KB | Image | download |
Fig. 4 | 62KB | Image | download |
【 图 表 】
Fig. 4
Fig. 1
Fig. 2
Fig. 1
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]