期刊论文详细信息
Frontiers in Public Health
Halo—A Universal Fluorescence Reader Based Threat Agent Detection Platform—A Proof of Concept Study Using SARS-CoV-2 Assays
article
Joseph Walish1  Jason Cox1  Jeremy Boone2  Jennifer Stone2  Nathan Henderson2  Molly Maloney2  Joe Ma3  Jonathan Maa3  Nghiem On3  Konrad Petre3  Bruce G. Goodwin4  Shanmuga Sozhamannan4  Robert Deans1 
[1] C2Sense, Inc.;MRIGlobal;Maxim Biomedical, Inc.;Joint Program Executive Office for Chemical;Logistics Management Institute
关键词: SARS-CoV-2;    diagnostics;    rapid antigen test;    immunoassay;    fluorescence;    europium;    handheld reader;    mobile app;   
DOI  :  10.3389/fpubh.2022.852083
学科分类:社会科学、人文和艺术(综合)
来源: Frontiers
PDF
【 摘 要 】

Polymerase chain reaction (PCR) remains the gold standard in disease diagnostics due to its extreme sensitivity and specificity. However, PCR tests are expensive and complex, require skilled personnel and specialized equipment to conduct the tests, and have long turnaround times. On the other hand, lateral flow immunoassay-based antigen tests are rapid, relatively inexpensive, and can be performed by untrained personnel at the point of care or even in the home. However, rapid antigen tests are less sensitive than PCR since they lack the inherent target amplification of PCR. It has been argued that rapid antigen tests are better indicators of infection in public health decision-making processes to test, trace, and isolate infected people to curtail further transmission. Hence, there is a critical need to increase the sensitivity of rapid antigen tests and create innovative solutions to achieve that goal. Herein, we report the development of a low-cost diagnostic platform, enabling rapid detection of SARS-CoV-2 under field or at-home conditions. This platform (Halo™) is a small, highly accurate, consumer-friendly diagnostic reader paired with fluorescently labeled lateral flow assays and custom software for collection and reporting of results. The focus of this study is to compare the analytical performance of Halo TM against comparable tests that use either colloidal gold nanoparticles or fluorescence-based reporters in simulated nasal matrix and not in clinical samples. Live virus data has demonstrated limit of detection performance of 1.9 TCID 50 /test in simulated nasal matrix for the delta variant, suggesting that single-assay detection of asymptomatic SARS-CoV-2 infections may be feasible. Performance of the system against all tested SARS CoV-2 virus variants showed comparable sensitivities indicating mutations in SARS-CoV-2 variants do not negatively impact the assay.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202301300001978ZK.pdf 463KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次