期刊论文详细信息
Saudi Journal of Biological Sciences
Reverse transcriptase loop-mediated isothermal amplification (RT-LAMP)-based diagnosis: A potential alternative to quantitative real-time PCR based detection of the novel SARS-COV-2 virus
Muhammad Faraz Arshad Malik1  Farhan Haq2  Aroosha Raja2  Imran Shabbir3  Mohammed S. Almuhayawi4  Hanaa Tashkandi5  Turki Al Amri6  Aamer Ikram7  Adnan Khurshid7  Salmaan Sharif7  Muhammad Salman7  Abdul Ahad7  Muhammad Suleman Rana7  Nazish Badar7  Steve Harakeh8  Esam I. Azhar8 
[1] Yousef Abdul Latif Jameel Scientific Chair of Prophetic Medicine Application, FM, KAU, Saudi Arabia;Department of Biosciences, COMSATS University of Islamabad, Pakistan;Department of Biotechnology and Bioinformatics, International Islamic University, Islamabad, Pakistan;Department of Microbiology and Parasitology, FM, KAU, Saudi Arabia;Department of Surgery, Faculty of Medicine (FM), King Abdulaziz University (KAU), Jeddah, Saudi Arabia;Family and Community Medicine Department, Faculty of Medicine in Rabigh, KAU, Jeddah, Saudi Arabia;National Institute of Health, Islamabad, Pakistan;Special Infectious Agents Unit, King Fahd Medical Research Center, Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, KAU, Saudi Arabia;
关键词: SARS-CoV-2;    COVID-19;    RT-LAMP;    qRT-PCR;    Detection;    RNA isolation;   
DOI  :  
来源: DOAJ
【 摘 要 】

The sudden outbreak of the novel Coronavirus infectious disease (COVID-19) resulted in significant challenges to global health systems. One of the primary challenges is rapid, reliable, and accurate detection of the severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) virus among the suspected COVID-19-infected individuals. At present, quantitative real-time PCR (qRT-PCR) is a widely used diagnostic method. However, it requires expensive instruments and expertise in the interpretation of results. These constraints reflect the significant need for the development of alternative diagnostic options.This study will validate the use and efficiency of the reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay as a potential alternative for the detection of COVID-19. For this purpose, a cohort of 297 suspected COVID-19 patients was tested using both the RT-LAMP assay and the conventional RT-PCR method. For the RT-LAMP assay, three genes (orf-1ab, N, and S) were identified as the target sites for the detection of COVID-19. Based on a comparative assessment, 117 out of 124 positive COVID-19 cases were observed using the RT-LAMP technique with an overall 91.45% sensitivity. Interestingly, where a consensus on 163 individuals free of SARS-Cov-2 was observed, RT-LAMP specificity was 90%. Based on these findings, the robustness of the technique, and the reduced dependency on expensive instrumentation, RT-LAMP-based COVID-19 detection is strongly recommended as a potential alternative assay.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:1次