Journal of Microwaves, Optoelectronics and Electromagnetic Applications | |
Testing strategies to evaluate non-oriented electrical steels losses | |
A. A. de Espíndola1  M. Rigoni2  P. Kuo-Peng2  J.P.A Bastos2  N. Sadowski2  J. P. Schlegel2  N. J. Batistela2  L.V. Dokonal3  | |
[1] EMBRACO;Universidade Federal de Santa Catarina;Whirlpool SA; | |
关键词: Non-oriented electrical steel; iron losses; iron losses measurement; Epstein frame test; ring core test; dynamometer test; | |
DOI : 10.1590/S2179-10742012000200008 | |
来源: DOAJ |
【 摘 要 】
This paper presents an experimental comparative study of iron losses obtained by means of the Epstein frame, Ring Core and dynamometer tests with non-oriented electrical steel samples. The comparisons are qualitative and they are intended to show the importance of carrying out other tests to evaluate electrical steels in addition to the standard Epstein frame method. In industry, complex or costly tests are avoided, whenever it is possible. This study shows that the ring core test can be a low cost solution since it is effective. For the manufacturer point of view, comparing different commercial steels at purchase time with a simple process is an advantage.
【 授权许可】
Unknown