期刊论文详细信息
World Journal of Surgical Oncology
A new feasible technique of mesh-reinforced pancreatojejunostomy and pancreatogastrostomy: retrospective analysis of 61 cases
关键词: Pancreatogastrostomy;    Pancreatojejunostomy;    Mesh;   
DOI  :  10.1186/1477-7819-10-114
来源: DOAJ
【 摘 要 】

Abstract

Background

Pancreatic leak was the major concern after pancreatoduodenectomy.

Methods

A total of 61 patients who underwent mesh-reinforced pancreatojejunostomy or pancreatogastrostomy from August 2005 to November 2011 were retrospectively analyzed.

Results

The mean anastomosis time of mesh-reinforced pancreatojejunostomy was 25 minutes ranging from 22 to 35 minutes. In mesh-reinforced pancreatogastrostomy, the mean anastomosis time ranged from 20 to38 minutes with an average of 30 minutes. Blood loss was 200 to 4,000 ml with an average of 710 ml in all patients. There was one case of pancreatic leak of Class A, three cases of pancreatic leak of Class B, one case of pancreatic leak of Class C, one case of choledochojejunostomy leakage, one case of gastrojejunostomy leakage, and three cases of abdominal bleeding.

Conclusion

As a new technique, mesh-reinforced pancreatojejunostomy and pancreatogastrostomy might be a safe and feasible procedure to prevent postoperative pancreatic leak.

Trial registration

This research is waivered from trial registration because it was a retrospective analysis of medical records.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次