期刊论文详细信息
Heliyon
Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
Takashi Ito1  Kentaro Okamoto2  Hajime Mizutani3  Keisuke Okubo4  Ichiro Yamamoto4  Shogo Takashiba4  Masahiro Ito4  Tadashi Yamamoto5  Masako Tai5  Yasuyoshi Shiota5  Shin Nakamura5  Yusuke Kawata6 
[1] Division of Dentistry, Tottori Municipal Hospital, 1-1 Matoba Tottori, Tottori 680-0501, Japan;Center for Innovative Clinical Medicine, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan;Dental Department Marketing Division, TAKARA BELMONT Corporation, 2-1-1 Higashishinsaibashi, Chuo-ku, Osaka 542-0083, Japan;Department of Pathophysiology - Periodontal Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan;Department of Periodontics and Endodontics, Okayama University Hospital, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan;Research and Development Department, TAKARA BELMONT Corporation, 2-1-1 Higashishinsaibashi, Chuo-ku, Osaka 542-0083, Japan;
关键词: Microbiology;    Biomedical devices;    Safety engineering;    Microorganism;    Biofilms;    Dentistry;   
DOI  :  
来源: DOAJ
【 摘 要 】

The prevention of nosocomial infections is an imperative task. The dental chair unit (DCU) is an indispensable device used in dental treatment. However, it is known that the dental unit water line (DUWL) can become contaminated with biofilm, consisting mainly of heterotrophic bacteria (HB). Recently, the International Organization for Standardization specified the methods for testing DUWL contamination management. On these grounds, a simulator reproducing DUWL was prepared to standardize the examination method of the DUWL contamination. Objectives: To evaluate the reproducibility of the DUWL simulator, monitor the DUWL contamination states, and test the efficacy of a commercial decontaminant for DUWL. Methods: The DUWL simulator was assembled by a DCU manufacturing company. The simulator's DUWL was filled with tap water (TW), and left for approximately one year. Neutral electrolyzed water (NEW) was used as a decontaminant for DUWL. Both TW and NEW were passed through DUWL in a timely manner simulating daily dental treatment. Water was sampled from the air turbine hand piece weekly for 4 weeks and used for HB culture. Contamination status was evaluated by measuring bacterial adenosine triphosphate release and by culturing on Reasoner's 2A medium. Results: The DUWL released contaminated water had a bacterial count of over 6 × 104 cfu/mL. After passing NEW through DUWL for 1 week, the count drastically decreased to its basal level and remained steady for 4 weeks. However, TW showed no effect on DUWL decontamination throughout the examination periods. Conclusions: The DUWL simulator could be useful to examine the efficacy of the decontaminant for DUWL and development of new methods in DUWL contamination management.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:6次