期刊论文详细信息
Journal of Electrical Bioimpedance
Rectifying memristor bridge circuit realized with human skin
Pabst Oliver1 
[1] Department of Physics, University of Oslo, Oslo, Norway;
关键词: bioimpedance;    non-linear electrical measurements;    human skin;    memristor;    rectification;   
DOI  :  10.2478/joeb-2018-0023
来源: DOAJ
【 摘 要 】

It has been demonstrated before that human skin can be modeled as a memristor (memory resistor). Here we realize a memristor bridge by applying two voltages of opposite signs at two different skin sites. By this setup it is possible to use human skin as a frequency doubler and half-wave rectifier which is an application of the non-linear electrical properties of human skin. The corresponding electrical measurements are non-linear since these are affected by the applied stimulus itself.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次