Visual Computing for Industry, Biomedicine, and Art | |
Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography | |
Yasuaki Sakano1  Masami Goto1  Hiroyuki Daida1  Keisuke Usui1  Shinsuke Kyougoku1  Koichi Ogawa2  | |
[1] Department of Radiological Technology, Faculty of Health Science, Juntendo University;Faculty of Science and Engineering, Hosei University; | |
关键词: Deep learning; Convolutional neural network; Low-dose computed tomography; Denoising; Image quality; | |
DOI : 10.1186/s42492-021-00087-9 | |
来源: DOAJ |
【 摘 要 】
Abstract To minimize radiation risk, dose reduction is important in the diagnostic and therapeutic applications of computed tomography (CT). However, image noise degrades image quality owing to the reduced X-ray dose and a possible unacceptably reduced diagnostic performance. Deep learning approaches with convolutional neural networks (CNNs) have been proposed for natural image denoising; however, these approaches might introduce image blurring or loss of original gradients. The aim of this study was to compare the dose-dependent properties of a CNN-based denoising method for low-dose CT with those of other noise-reduction methods on unique CT noise-simulation images. To simulate a low-dose CT image, a Poisson noise distribution was introduced to normal-dose images while convoluting the CT unit-specific modulation transfer function. An abdominal CT of 100 images obtained from a public database was adopted, and simulated dose-reduction images were created from the original dose at equal 10-step dose-reduction intervals with a final dose of 1/100. These images were denoised using the denoising network structure of CNN (DnCNN) as the general CNN model and for transfer learning. To evaluate the image quality, image similarities determined by the structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were calculated for the denoised images. Significantly better denoising, in terms of SSIM and PSNR, was achieved by the DnCNN than by other image denoising methods, especially at the ultra-low-dose levels used to generate the 10% and 5% dose-equivalent images. Moreover, the developed CNN model can eliminate noise and maintain image sharpness at these dose levels and improve SSIM by approximately 10% from that of the original method. In contrast, under small dose-reduction conditions, this model also led to excessive smoothing of the images. In quantitative evaluations, the CNN denoising method improved the low-dose CT and prevented over-smoothing by tailoring the CNN model.
【 授权许可】
Unknown