Przegląd Spawalnictwa | |
Influence of vacuum brazing temperature on the microstructure of an Inconel 783 superalloy joint with a honeycomb sealing made of Hastelloy X superalloy | |
Irena Dul1  Kamil Krystek2  Maciej Motyka3  | |
[1] ;Pratt & Whitney;Rzeszow University of Technology; | |
关键词: Inconel 783; Hastelloy X; vacuum brazing; honeycomb sealing; | |
DOI : 10.26628/wtr.v91i9.1061 | |
来源: DOAJ |
【 摘 要 】
The purpose of this work was to assess the influence ofbrazing temperature on microstructure of the cobalt-based Inconel 783 superalloy joint with nickel-based Hastelloy X superalloy ‒ seal shaped in honeycomb structure. Brazing process was combined with solution heat treatment of Inconel 783 in one operation. Nickel based brazing filler metal from BNi-2 group was used. Tests were conducted in 1121 °C (solutionizing temperature), 1075 °C and 1030 °C in 1 hour. Subsequently, metallographic investigations were made using optical and scanning electron microscopes, mainly focused on changes in a seal made of Hastelloy X, where joint erosion in higher temperature was observed.
【 授权许可】
Unknown