期刊论文详细信息
Journal of Cardiovascular Magnetic Resonance
Quantification correction for free-breathing myocardial T1ρ mapping in mice using a recursively derived description of a T1ρ* relaxation pathway
Paula-Anahi Arias-Loza1  Peter Nordbeck2  Daniel Gensler2  Kolja Lau2  Maximilian Gram2  Fabian Tobias Gutjahr3  Peter Michael Jakob3  Petra Albertova3 
[1] Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg;Department of Internal Medicine I, University Hospital Würzburg;Experimental Physics 5, University of Würzburg;
关键词: T1rho;    T1ρ;    Spin-lock;    Mapping;    Quantitative MRI;    Correction;   
DOI  :  10.1186/s12968-022-00864-2
来源: DOAJ
【 摘 要 】

Abstract Background Fast and accurate T1ρ mapping in myocardium is still a major challenge, particularly in small animal models. The complex sequence design owing to electrocardiogram and respiratory gating leads to quantification errors in in vivo experiments, due to variations of the T1ρ relaxation pathway. In this study, we present an improved quantification method for T1ρ using a newly derived formalism of a T1ρ* relaxation pathway. Methods The new signal equation was derived by solving a recursion problem for spin-lock prepared fast gradient echo readouts. Based on Bloch simulations, we compared quantification errors using the common monoexponential model and our corrected model. The method was validated in phantom experiments and tested in vivo for myocardial T1ρ mapping in mice. Here, the impact of the breath dependent spin recovery time Trec on the quantification results was examined in detail. Results Simulations indicate that a correction is necessary, since systematically underestimated values are measured under in vivo conditions. In the phantom study, the mean quantification error could be reduced from − 7.4% to − 0.97%. In vivo, a correlation of uncorrected T1ρ with the respiratory cycle was observed. Using the newly derived correction method, this correlation was significantly reduced from r = 0.708 (p < 0.001) to r = 0.204 and the standard deviation of left ventricular T1ρ values in different animals was reduced by at least 39%. Conclusion The suggested quantification formalism enables fast and precise myocardial T1ρ quantification for small animals during free breathing and can improve the comparability of study results. Our new technique offers a reasonable tool for assessing myocardial diseases, since pathologies that cause a change in heart or breathing rates do not lead to systematic misinterpretations. Besides, the derived signal equation can be used for sequence optimization or for subsequent correction of prior study results.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次