Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking
Philipp Kastner1  Firas Souleiman1  Markus Windolf1  Jan Buschbaum1  Boyko Gueorguiev1  Torsten Pastor1  Tatjana Pastor2  Matthias Knobe3 
[1] AO Research Institute Davos, 7270 Davos, Switzerland;Department of Hand Surgery, Bern University Hospital, University of Bern, 8008 Bern, Switzerland;Department of Orthopedic and Trauma Surgery, Lucerne Cantonal Hospital, 6000 Lucerne, Switzerland;
关键词: education;    simulation;    distal interlocking;    intramedullary nailing;    training;   
DOI  :  10.3390/medicina58060773
来源: DOAJ
【 摘 要 】

Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated training could help overcome these problems. The aim of this study was to assess construct and face validity of new Digitally Enhanced Hands-On Surgical Training (DEHST) concept and device for training of distal interlocking of intramedullary nails. Materials and Methods: Twenty-nine novices and twenty-four expert surgeons performed interlocking on a DEHST device. Construct validity was evaluated by comparing captured performance metrics—number of X-rays, nail hole roundness, drill tip position and drill hole accuracy—between experts and novices. Face validity was evaluated with a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale. Results: Face validity: mean realism of the training device was rated 6.3 (range 4–7). Training potential and need for distal interlocking training were both rated with a mean of 6.5 (range 5–7), with no significant differences between experts and novices, p ≥ 0.234. All participants (100%) stated that the device is useful for procedural training of distal nail interlocking, 96% wanted to have it at their institution and 98% would recommend it to colleagues. Construct validity: total number of X-rays was significantly higher for novices (20.9 ± 6.4 versus 15.5 ± 5.3, p = 0.003). Success rate (ratio of hit and miss attempts) was significantly higher for experts (novices hit: n = 15; 55.6%; experts hit: n = 19; 83%, p = 0.040). Conclusion: The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was proven by reliably discriminating between experts and novices. Participants indicate high further training potential as the device may be easily adapted to other surgical tasks.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次