期刊论文详细信息
Results in Engineering
Structural behavior of expanded rib steel bars used in reinforced concrete beams
Ki-Tae Park1  Kun-Soo Kim2  Changjin Park2 
[1]Corresponding author.
[2]Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-Ro, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do, 10223, South Korea
关键词: Expanded rib bar;    Headed bar;    Beam test;    Strength;    Ductility;   
DOI  :  
来源: DOAJ
【 摘 要 】
Conventional headed rebar is advantageous in reducing embedment depth and simplifying construction; however, they are subject to concentrated stresses at the anchor point which can lead to failure of the structural element. To alleviate the stress concentration and avoid failure, rebars with numerous expanded ribs are proposed herein. The effects of expanded rib bars were investigated by comparing a jointed specimen with an expanded rib bar joint to a specimen with a conventional headed bar and an unjointed continuously reinforced specimen using the four-point bending test. The maximum strength, displacement ductility, cracking analysis, and rebar strain were recorded and analyzed. In terms of structural performance, the expanded rib bars outperformed the conventional headed bars and were equivalent to the unjointed continuously reinforced sections.
【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次