期刊论文详细信息
IEEE Photonics Journal
Pupil Size Estimation Based on Spatially Weighted Corneal Flux Density
Yuning Zhang1  Yan Tu1  Shuai Li1  Baoping Wang1  Ping Wang1  Xiaohua Li1  Jiang Wang1 
[1] Joint International Research Laboratory of Information Display and Visualization, School of Electronic Science & Engineering, Southeast University, Nanjing, China;
关键词: Pupil Size;    corneal flux density;    display luminance;    light environment;    visual optics.;   
DOI  :  10.1109/JPHOT.2019.2948223
来源: DOAJ
【 摘 要 】

The pupil size is an important parameter in different studies on vision and ophthalmology. A pupil size estimation model is constantly needed when actual measurements are unavailable. The reported pupil estimation models commonly adopt the product of light intensity and viewing field area, supposing the light contributes uniformly across the spatial domain. In this paper, the pupil diameters were measured for stimuli with different intensities and different sizes. Spatially varying effect were observed, especially for large field stimuli and annular bright stimuli. A spatially weighted flux density is proposed which shows a high correlation with pupil diameters. A hyperbolic equation is fitted to estimate the natural pupil diameter with independent light spatial distributions. The goodness of fit R2 reaches 0.97. The accuracy of the model is further verified with a natural indoor scene for different viewing distances and different illumination levels. The model predicted pupil diameters show a high correlation with the measured data.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次