Archives of Electrical Engineering | |
Comparison of higher harmonic contents in salient pole synchronous generator with different rotor construction | |
Nadolski Roman1  Staszak Jan1  Ludwinek Krzysztof1  | |
[1] Kielce University of Technology, Department of Automatic Control and Computer Science, Tysiąclecia P. P. 7, 25-314 Kielce, Poland, tel. +48 41 342 46 82; | |
关键词: salient pole synchronous generator; higher harmonics; solid rotor; rotor with radial incisions; laminated rotor; | |
DOI : 10.1515/aee-2017-0009 | |
来源: DOAJ |
【 摘 要 】
The paper presents a comparison of higher harmonics in induced phase voltages of a stator winding in the no-load state of a three-phase 5.5 kVA salient pole synchronous generator. The comparison is carried out for the synchronous generator with different salient pole rotor constructions: a non-skewed solid rotor, a non-skewed solid rotor with radial incisions, and a laminated electrotechnical steel rotor with skewed slots and damping bars. The calculations of higher harmonics are based on the magnetic field distributions in the air gap, which are carried out in a 2D model in a FEMM program and on the induced voltage waveforms in the stator windings registered during experimental investigations of the 5.5 kVA salient pole synchronous generator in the no-load state.
【 授权许可】
Unknown