| Water | |
| Leak Signature Space: An Original Representation for Robust Leak Location in Water Distribution Networks | |
| Vicenç Puig1  Luis E. Garza-Castañón2  Adriana Vargas-Martinez2  Myrna V. Casillas2  | |
| [1] Department of Automatic Control, Universitat Politècnica de Catalunya (UPC), Barcelona 08028, Spain;Tecnológico de Monterrey, Campus Monterrey, Monterrey 64849, Mexico; | |
| 关键词: water distribution networks; leak location; linear model approximation; leak signature space; | |
| DOI : 10.3390/w7031129 | |
| 来源: DOAJ | |
【 摘 要 】
In this paper, an original model-based scheme for leak location using pressure sensors in water distribution networks is introduced. The proposed approach is based on a new representation called the Leak Signature Space (LSS) that associates a specific signature to each leak location being minimally affected by leak magnitude. The LSS considers a linear model approximation of the relation between pressure residuals and leaks that is projected onto a selected hyperplane. This new approach allows to infer the location of a given leak by comparing the position of its signature with other leak signatures. Moreover, two ways of improving the method’s robustness are proposed. First, by associating a domain of influence to each signature and second, through a time horizon analysis. The efficiency of the method is highlighted by means of a real network using several scenarios involving different number of sensors and considering the presence of noise in the measurements.
【 授权许可】
Unknown