科技报告详细信息
| Hanford Single-Shell Tank Leak Causes and Locations - 241-B Farm | |
| Girardot, Crystal L.1  Harlow, Donald G.1  | |
| [1] Washington River Protection Systems, Richland, WA (United States) | |
| 关键词: leak location; leak cause; tank; integrity assessment; B Farm; leak assessment; | |
| DOI : 10.2172/1087727 RP-ID : RPP-RPT-54913 Rev 0 PID : OSTI ID: 1087727 Others : TRN: US1300139 |
|
| 学科分类:核能源与工程 | |
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201704180002353LZ | 2675KB |
PDF