The effect of preanalytical mechanical mixing time on complete blood cell count parameters in the emergency laboratory
Turan Turhan1  Esin Calci1  Cigdem Yucel2 
[1] Ankara Numune Egitim ve Arastirma Hastanesi;Ankara Numune Egitim ve Arastirma Hastanesi;
关键词: Complete blood count;    preanalytical factors;    mechanical mixing;    emergency laboratory;   
DOI  :  10.5455/medscience.2016.05.8552
来源: DOAJ
【 摘 要 】

Complete blood count (CBC) is one of the most common laboratory tests. Preanalytical factors like specimen homogenization affect the CBC test results. In the emergency laboratory, test time is a ciritcal parameter. Optimization of test procedures is of critical importance to give more accurate results in a shorter time period. This study was designed to evaluate the effects of preanalytical mechanical mixing times on CBC parameters and to optimize the mechanical mixing time for the analysis. Mechanical mixing time of 1 and 5 minutes (t= 1 and t=5 respectively)with a rotary type mixer and automatic mixing performed by the Coulter LH 780 (t=0) prior to complete blood count analysis were evaluated. Between t=0 and t=1 minutes of mechanical mixing, only a significant change in MPV values were obtained (p [Med-Science 2017; 6(2.000): 255-9]