期刊论文详细信息
Viruses 卷:12
Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay
on behalf of INMI ReCOVeRI Study Group1  Emanuele Nicastri2  Andrea Antinori2  Nicola Petrosillo2  Luisa Marchioni2  Evangelo Boumis2  Franco Locatelli3  Alimuddin Zumla4  Pierluca Piselli5  Francesca Colavita6  Licia Bordi6  Giuseppe Sberna6  Maria Rosaria Capobianchi6  Eleonora Lalle6  Concetta Castilletti6  Giulia Minnucci7  Elena D’Agostini7  Giuseppe Ippolito8 
[1] ;
[2] Clinical Department, National Institute for Infectious Diseases “L. Spallanzani” IRCCS, 00149 Rome, Italy;
[3] Department of Pediatric Hematology and Oncology, IRCCS Ospedale Pediatrico Bambino Gesù, 00165 Rome, Italy;
[4] Division of Infection and Immunity, University College London, London WC1E 6BT, UK;
[5] Epidemiology Department, National Institute for Infectious Diseases “L. Spallanzani” IRCCS, 00149 Rome, Italy;
[6] Laboratory of Virology, National Institute for Infectious Diseases “L. Spallanzani” IRCCS, 00149 Rome, Italy;
[7] R&D Department, DiaSorin Molecular LLC, Cypress, CA 90630, USA;
[8] Scientific Direction, National Institute for Infectious Diseases “L. Spallanzani” IRCCS, 00149 Rome, Italy;
关键词: SARS-CoV-2 RNA;    oral fluid;    real time RT-PCR;    direct assay;   
DOI  :  10.3390/v12101184
来源: DOAJ
【 摘 要 】

Background: RT-PCR on nasopharyngeal (NPS)/oropharyngeal swabs is the gold standard for diagnosis of SARS-CoV-2 infection and viral load monitoring. Oral fluid (OF) is an alternate clinical sample, easy and safer to collect and could be useful for COVID-19 diagnosis, monitoring viral load and shedding. Methods: Optimal assay conditions and analytical sensitivity were established for the commercial Simplexa™ COVID-19 Direct assay adapted to OF matrix. The assay was used to test 337 OF and NPS specimens collected in parallel from 164 hospitalized patients; 50 bronchoalveolar lavage (BAL) specimens from a subgroup of severe COVID-19 cases were also analysed. Results: Using Simplexa™ COVID-19 Direct on OF matrix, 100% analytical detection down to 1 TCID50/mL (corresponding to 4 × 103 copies (cp)/mL) was observed. No crossreaction with other viruses transmitted through the respiratory toute was observed. Parallel testing of 337 OF and NPS samples showed highly concordant results (κ = 0.831; 95 % CI = 0.771–0.891), and high correlation of Ct values (r = 0.921; p < 0.0001). High concordance and elevated correlation was observed also between OF and BAL. Prolonged viral RNA shedding was observed up to 100 days from symptoms onset (DSO), with 32% and 29% positivity observed in OF and NPS samples, respectively, collected between 60 and 100 DSO. Conclusions: Simplexa™ COVID-19 Direct assays on OF have high sensitivity and specificity to detect SARS-CoV-2 RNA and provide an alternative to NPS for diagnosis and monitoring SARS-CoV-2 shedding.

【 授权许可】

Unknown   

  文献评价指标  
  下载次数:0次 浏览次数:0次