| Radiation Oncology | |
| Evaluation of plan robustness on the dosimetry of volumetric arc radiotherapy (VMAT) with set-up uncertainty in Nasopharyngeal carcinoma (NPC) radiotherapy | |
| Qi Zeng1  Suyan Bi1  Zhitao Dai1  Zhen Ding1  Jun Ma1  Xiaoyong Xiang1  Kailian Kang1  | |
| [1] Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital and Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 113 Baohe Rd, Longgang District, 518116, Shenzhen City, Guangdong Province, People’s Republic of China; | |
| 关键词: Robustness; Tumor control probability; Normal tissue complication probability; Set-up uncertainty; | |
| DOI : 10.1186/s13014-021-01970-8 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
PurposeTo evaluate the sensitivity to set up the uncertainty of VMAT plans in Nasopharyngeal carcinoma (NPC) treatment by proposing a plan robustness evaluation method.Methods10 patients were selected for this study. A 2-arc volumetric-modulated arc therapy (VMAT) plan was generated for each patient using Varian Eclipse (13.6 Version) treatment planning system (TPS). 5 uncertainty plans (U-plans) were recalculated based on the first 5 times set-up errors acquired from cone-beam computer tomography (CBCT). The dose differences of the original plan and perturbed plan corresponded to the plan robustness for the structure. Tumor control probability (TCP) and normal tissues complication probability (NTCP) were calculated for biological evaluation.ResultsThe mean dose differences of D98% and D95% (ΔD98% and ΔD95%) of PTVp were respectively 3.30 Gy and 2.02 Gy. The ΔD98% and ΔD95% of CTVp were 1.12 Gy and 0.58 Gy. The ΔD98% and ΔD95% of CTVn were 1.39 Gy and 1.03 Gy, distinctively lower than those in PTVn (2.8 Gy and 2.0 Gy). The CTV-to-PTV margin increased the robustness of CTVs. The ΔD98% and ΔD95% of GTVp were 0.56 Gy and 0.33 Gy. GTVn exhibited strong robustness with little variation of D98% (0.64 Gy) and D95% (0.39 Gy). No marked mean dose variations of Dmean were seen. The mean reduction of TCP (ΔTCP) in GTVp and CTVp were respectively 0.4% and 0.3%. The mean ΔTCPs of GTVn and CTVn were 0.92% and 1.3% respectively. The CTV exhibited the largest ΔTCP (2.2%). In OARs, the brain stem exhibited weak robustness due to their locations in the vicinity of PTV. Bilateral parotid glands were sensitive to set-up uncertainty with a mean reduction of NTCP (ΔNTCP) of 6.17% (left) and 7.70% (right). The Dmax of optical nerves and lens varied slightly.ConclusionVMAT plans had a strong sensitivity to set-up uncertainty in NPC radiotherapy, with increasing risk of underdose of tumor and overdose of vicinal OARs. We proposed an effective method to evaluate the plan robustness of VMAT plans. Plan robustness and complexity should be taken into account in photon radiotherapy.
【 授权许可】
CC BY
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202203116332898ZK.pdf | 1868KB |
PDF