期刊论文详细信息
BMC Musculoskeletal Disorders
Marker- three dimensional measurement versus traditional radiographic measurement in the treatment of tibial fracture using Taylor spatial frame
Sida Liu1  Jinli Zhang2  Tao Zhang2  Xuefei Fu3  Xingpeng Zhang4  Hong Li5  Yanshi Liu6  Qixin Liu7 
[1] College of Mechanical Engineering, Tianjin University, Tianjin, China;Department of Orthopedics and Trauma, Tianjin Hospital, Tianjin, China;Department of Orthopedics, Anhui No.2 Provincial People’s Hospital, Hefei, Anhui, China;Department of Orthopedics, Shanghai Pudong New Area People’s Hospital, Shanghai, China;Department of Orthopedics, Zigong Fourth People’s Hospital, Zigong, Sichuan, China;Department of Trauma and Microreconstructive surgery, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China;Graduate College of Tianjin Medical University, Tianjin, China;
关键词: External fixation;    Taylor spatial frame;    Three-dimensional reconstruction;    Tibial fracture;   
DOI  :  10.1186/s12891-022-05112-3
来源: Springer
PDF
【 摘 要 】

BackgroundThe Taylor Spatial Frame (TSF) has been widely used for tibial fracture. However, traditional radiographic measurement method is complicated and the reduction accuracy is affected by various factors. The purpose of this study was to propose a new marker- three dimensional (3D) measurement method and determine the differences of reduction outcomes, if any, between marker-3D measurement method and traditional radiographic measurement in the TSF treatment.MethodsForty-one patients with tibial fracture treated by TSF in our institution were retrospectively analyzed from January 2016 to June 2019, including 21 patients in the marker-3D measurement group (experimental group) and 20 patients in the traditional radiographic measurement group (control group). In the experimental group, 3D reconstruction with 6 markers installed on the TSF was performed to determine the electronic prescription. In the control group, the anteroposterior (AP) and lateral radiographs were performed for the traditional parameter measurements. The effectiveness was evaluated by the residual displacement deformity (RDD) and residual angle deformity (RAD) in the coronal and sagittal plane, according to the AP and lateral X-rays after reduction.ResultsAll patients achieved functional reduction. The residual RDD in AP view was 0.5 (0, 1.72) mm in experimental group and 1.74 (0.43, 3.67) mm in control group. The residual RAD in AP view was 0 (0, 1.25) ° in experimental group and 1.25 (0.62, 1.95) °in control group. As for the lateral view, the RDD was 0 (0, 1.22) mm in experimental group and 2.02 (0, 3.74) mm in control group, the RAD was 0 (0, 0) ° in experimental group and 1.42 (0, 1.93) ° in control group. Significant differences in all above comparisons were observed between the two groups (AP view RDD: P = 0.024, RAD: P = 0.020; Lateral view RDD: P = 0.016, RAD: P = 0.004).ConclusionsThe present study introduced a marker-3D measurement method to complement the current TSF treatment. This method avoids the manual measurement error and improves the accuracy of fracture reduction, providing potential advantages of bone healing and function rehabilitation.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202202180095218ZK.pdf 3002KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:1次