期刊论文详细信息
Radiation Oncology
Applications of various range shifters for proton pencil beam scanning radiotherapy
Curtiland Deville1  Stefan Both2  Zelig Tochner3  James McDonough3  Jiajian Shen4  Minglei Kang5  Qing Chen5  Charles B. Simone5  Chengyu Shi5  Haibo Lin5  Huifang Zhai5  Sheng Huang5 
[1] Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, 21231, Baltimore, MD, USA;Department of Radiation Oncology, University Medical Center Groningen, 9713 GZ, Groningen, Netherlands;Department of Radiation Oncology, University of Pennsylvania, 19104, Philadelphia, PA, USA;Mayo Clinic, 85054, Phoenix, AZ, USA;New York Proton Center, 10035, New York, USA;
关键词: Proton therapy;    Pencil beam scanning (PBS);    Range shifter;    Bolus;   
DOI  :  10.1186/s13014-021-01873-8
来源: Springer
PDF
【 摘 要 】

BackgroundA range pull-back device, such as a machine-related range shifter (MRS) or a universal patient-related range shifter (UPRS), is needed in pencil beam scanning technique to treat shallow tumors.MethodsThree UPRS made by QFix (Avondale, PA, USA) allow treating targets across the body: U-shaped bolus (UB), anterior lateral bolus (ALB), and couch top bolus. Head-and-neck (HN) patients who used the UPRS were tested. The in-air spot sizes were measured and compared in this study at air gaps: 6 cm, 16 cm, and 26 cm. Measurements were performed in a solid water phantom using a single-field optimization pencil beam scanning field with the ALB placed at 0, 10, and 20 cm air gaps. The two-dimensional dose maps at the middle of the spread-out Bragg peak were measured using ion chamber array MatriXX PT (IBA-Dosimetry, Schwarzenbruck, Germany) located at isocenter and compared with the treatment planning system.ResultsA UPRS can be consistently placed close to the patient and maintains a relatively small spot size resulting in improved dose distributions. However, when a UPRS is non-removable (e.g. thick couch top), the quality of volumetric imaging is degraded due to their high Z material construction, hindering the value of Image-Guided Radiation Therapy (IGRT). Limitations of using UPRS with small air gaps include reduced couch weight limit, potential collision with patient or immobilization devices, and challenges using non-coplanar fields with certain UPRS. Our experience showed the combination of a U-shaped bolus exclusively for an HN target and an MRS as the complimentary device for head-and-neck targets as well as for all other treatment sites may be ideal to preserve the dosimetric advantages of pencil beam scanning proton treatments across the body.ConclusionWe have described how to implement UPRS and MRS for various clinical indications using the PBS technique, and comprehensively reviewed the advantage and disadvantages of UPRS and MRS. We recommend the removable UB only to be employed for the brain and HN treatments while an automated MRS is used for all proton beams that require RS but not convenient or feasible to use UB.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202109175859124ZK.pdf 1624KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:2次