Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography
article
Lin Yang1  Meng Dai2  Knut Möller3  Inéz Frerichs4  Andy Adler5  Feng Fu2  Zhanqi Zhao2 
[1] Department of Aerospace Medicine, Fourth Military Medical University;Department of Biomedical Engineering, Fourth Military Medical University;Institute of Technical Medicine, Furtwangen University;Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel;Department of Systems and Computer Engineering, Carleton University;3 Institute of Technical Medicine, Furtwangen University
关键词: Global inhomogeneity index;    electrical impedance tomography;    CT segmentation;    ventilation heterogeneity;    acute respiratory distress syndrome (ARDS);   
DOI  :  10.21037/qims-20-682
学科分类:外科医学
来源: AME Publications
PDF
【 摘 要 】

Background: The global inhomogeneity ( GI ) index is a functional electrical impedance tomography (EIT) parameter which is used clinically to assess ventilation distribution. However, GI may underestimate the actual heterogeneity when the size of lung regions is underestimated. We propose a novel method to use anatomical information to correct the GI index calculation. Methods: EIT measurements were performed at the level of the fifth intercostal space in six patients with acute respiratory distress syndrome. The thorax and lungs were segmented automatically from serial individual CT scans. The anatomically derived lung regions were calculated in EIT images from simulating a homogeneous ventilation distribution in a finite element model. The conventional approach ( GI meas,func ), analyzes images in functionally-defined lung regions, while our proposed measure ( GI meas,anat ) is based on analysis in anatomically-defined regions. We additionally define a simulated comparison ( GI sim,anat ) to determine the lower limit of the GI measure for a homogenous distribution of ventilation. Results: As expected, the conventional GI meas,func [0.382 (0.088), median (interquartile range)] were significantly lower than the proposed GI meas,anat [0.823 (0.152), P<0.05], and were much closer to the lower limit GI sim,anat [0.343 (0.039)]. Both GI meas,anat and GI meas,func were strongly correlated with arterial oxygen partial pressure to fractional inspired oxygen ratio (R=−0.88, P<0.05), whereas GI sim,anat (R=0.23) was not. GI meas,anat had a linear-regression slope 3.2 times that of GI meas,func suggesting a higher sensitivity to the changes in lung condition. Conclusions: The proposed GI meas,anat (or shortened as GI anat ) is an improved measure of ventilation inhomogeneity over GI, and better reflects portion of non-ventilated regions due to alveolar collapse or overdistension.

【 授权许可】

All Rights reserved   

【 预 览 】
附件列表
Files Size Format View
RO202108210002515ZK.pdf 1583KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次