Malaria Journal
Evaluation of a novel real-time PCR assay for the detection, identification and quantification of Plasmodium species causing malaria in humans
Toon Stuitje1  Kim van Bergen2  Robert Akkers2  Rob Castel2  Eric Vermeer2  Theo Mank3 
[1]MRC Holland, Willem Schoutenstraat 1, 1057 DL, Amsterdam, The Netherlands
[2]Result Laboratorium, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, The Netherlands
[3]Streeklaboratorium Voor de Volksgezondheid Kennemerland, Boerhaavelaan 26, 2035 RC, Haarlem, The Netherlands
关键词: Malaria;    Real-time PCR;    Melting curve analysis;    Plasmodium;   
DOI  :  10.1186/s12936-021-03842-8
来源: Springer
PDF
【 摘 要 】
BackgroundThe entry of PCR-based techniques into malaria diagnostics has improved the sensitivity and specificity of the detection of Plasmodium infections. It has been shown that humans are regularly infected by at least six different Plasmodium species. The MC004 real-time PCR assay for malaria diagnosis is a novel single-tube assay that has been developed for the purpose of simultaneously detecting all Plasmodium species known to infect humans, and discrimination between Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae, Plasmodium ovale wallikeri, Plasmodium ovale curtisi, Plasmodium knowlesi (including differentiation of three strains) and Plasmodium cynomolgi (including differentiation of three strains). Detection and identification of Plasmodium species relies on molecular beacon probe-based melting curve analysis. In addition, this assay might be used to quantify the parasitaemia of at least P. falciparum by calculating the level of parasitaemia directly from the Cq-value.MethodsThe samples used in this study comprised reference samples, patient samples, and synthetic controls. The following analytical performance characteristics of the MC004 assay were determined: analytical specificity, limit of detection, the ability to detect mixed infections, and the potential to determine the level of parasitaemia of P. falciparum, including assessment of within-run and between-run precisions.ResultsNo false positive or false negative results were observed. The limit of detection of P. falciparum was 1 × 10–3 IU/mL (WHO standard). Mixed infections with P. falciparum and non-falciparum species were correctly identified. A calibration curve could be established to quantify the parasitaemia of at least P. falciparum. The within-run and between-run precisions were less than 20% CV at the tested parasitaemia levels of 0.09%, 0.16%, 2.15% and 27.27%.ConclusionBased upon the analytical performance characteristics that were determined, the MC004 assay showed performance suitable for use in clinical settings, as well as epidemiological studies.
【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202108120923547ZK.pdf 2328KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:3次