Sonication fluid culture of antibiotic-loaded bone cement spacer has high accuracy to confirm eradication of infection before reimplantation of new prostheses
Jinglin Wu1  Jun Dong2  Fanxiao Liu2  Qingyu Zhang2  Baocong Ding3 
[1] Basic Course Department, Weihai Vocational College, New Sci-Tech Park of Beihai, 264200, Weihai, Shandong, China;Department of Orthopedics, Shandong Provincial Hospital affiliated to Shandong First Medical University, No.324, Road Jing Wu Wei Qi, 250021, Jinan, Shandong, China;Rehabilitation Department, Shandong University of Traditional Chinese Medicine Affiliated Hospital, No.16369, Road Jing Shi, 250014, Jinan, Shandong, China;
关键词: Periprosthetic joint infection;    Sonication culture;    Spacer;    Meta-analysis;   
DOI  :  10.1186/s13018-021-02520-4
来源: Springer
PDF
【 摘 要 】

BackgroundSonication fluid culture of antibiotic-loaded bone cement spacer has been used to predict reinfection of two-stage revision, but its value remains disputable. This study aims to evaluate the association between the culture result of the sonicated spacer and the status of patients with periprosthetic joint infection receiving two-stage revision.Materials and methodsA comprehensive electronic literature search was performed through four databases including PubMed, Embase/Ovid, and EBSCO, and the Cochrane Library to retrieve studies in which sonication fluid culture of the antibiotic spacer was conducted before reimplantation. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were calculated to assess the association between the culture result of sonicated spacer and prognosis of the two-stage revision.ResultsEleven eligible studies comprising 603 artificial joints with PJI (134 suffering a clinical failure of two-stage revision) were included in the quantitative analysis. The pooled incidences of positive culture of sonicated spacer and intraoperative tissue were 0.14 (95% confidence interval [CI] 0.08–0.21) and 0.14 (95% CI 0.08–0.20), respectively. A positive culture of sonicated antibiotic-loaded bone cement spacer illustrated moderate sensitivity (0.31, 95% CI 0.13–0.58) but high specificity (0.94, 95% CI 0.86–0.98) for the diagnosis of therapeutic failure of two-stage revision; the pooled DOR was 7.67 (95% CI, 3.63–16.22). Meanwhile, the pooled sensitivity, specificity, and DOR of intraoperative tissue culture during the two-stage revision to predict therapeutic failure were 0.32 (95% CI, 0.20–0.47), 0.96 (95% CI, 0.92–0.98), and 10.62 (95% CI, 4.90–23.01), respectively.ConclusionsSonication fluid culture of antibiotic-loaded bone cement spacer revealed high accuracy for confirming eradication of infection before reimplantation of new prostheses and therefore could be used as a supplement for assessing therapeutic effect for PJI. However, both sonication fluid culture and intraoperative tissue culture from antibiotic-loaded bone cement spacer showed restricted yield for the prediction of a septic failure after the two-stage revision of PJI. Large-scale, prospective studies are still needed to testify current findings.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107226039338ZK.pdf 2183KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:1次