期刊论文详细信息
Frontiers in Cellular and Infection Microbiology
Development and Evaluation of the Rapid and Sensitive RPA Assays for Specific Detection of Salmonella spp. in Food Samples
Zhimin Chen1  Jinfeng Wang1  Xiao Xia Sun1  Jianchang Wang1  Ya-nan Guo2  Liwei Zhao2  Pingping Chen2  Mengyuan Dong2  Yuanyuan Wang2  Weijuan Gao2  Yunyun Geng2  Xiangdong Xu3 
[1] Food Microbiology and Animal Quarantine Laboratory, Technology Center of Shijiazhuang Customs, Shijiazhuang, China;Heibei Key Laboratory of Chinese Medicine Research on Cardiocerebrovascular Disease, Hebei University of Chinese Medicine, Shijiazhuang, China;School of Public Health, Key Laboratory of Environment and Human Health, Hebei Medical University, Shijiazhuang, China;
关键词: Salmonella;    invA;    real-time RPA;    lateral flow strip (LFS);    isothermal amplification;   
DOI  :  10.3389/fcimb.2021.631921
来源: Frontiers
PDF
【 摘 要 】

Salmonella spp. is among the main foodborne pathogens which cause serious foodborne diseases. An isothermal real-time recombinase polymerase amplification (RPA) and lateral flow strip detection (LFS RPA) were used to detect Salmonella spp. targeting the conserved sequence of invasion protein A (invA). The Real-time RPA was performed in a portable florescence scanner at 39°C for 20 min. The LFS RPA was performed in an incubator block at 39°C for 15 min, under the same condition that the amplifications could be inspected by the naked eyes on the LFS within 5 min. The detection limit of Salmonella spp. DNA using real-time RPA was 1.1 × 101 fg, which was the same with real-time PCR but 10 times higher than that of LFS RPA assay. Moreover, the practicality of discovering Salmonella spp. was validated with artificially contaminated lamb, chicken, and broccoli samples. The analyzing time dropped from 60 min to proximately 5–12 min on the basis of the real-time and LFS RPA assays compared with the real-time PCR assay. Real-time and LFS RPA assays’ results were equally reliable. There was no cross-reactivity with other pathogens in both assays. In addition, the assays had good stability. All of these helped to show that the developed RPA assays were simple, rapid, sensitive, credible, and could be a potential point-of-need (PON) test required mere resources.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107165468413ZK.pdf 734KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:2次