期刊论文详细信息
Frontiers in Pediatrics
Biomarker Potential of the Soluble Receptor for Advanced Glycation End Products to Predict Bronchopulmonary Dysplasia in Premature Newborns
Kenneth E. Nollet1  Mina Chishiki2  Hirotaka Ichikawa2  Kyohei Miyazaki2  Nozomi Kashiwabara2  Kei Ogasawara2  Maki Sato2  Yohei Kume2  Hayato Go2  Kenichi Sato2  Hajime Maeda2  Mitsuaki Hosoya2  Hitoshi Ohto3 
[1] Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University School of Medicine, Fukushima, Japan;Department of Pediatrics, Fukushima Medical University School of Medicine, Fukushima, Japan;Fukushima Medical University, Fukushima, Japan;
关键词: rage;    premature infants;    bronchopulmonary dysplasia;    biomarker;    serum;   
DOI  :  10.3389/fped.2021.649526
来源: Frontiers
PDF
【 摘 要 】

Bronchopulmonary dysplasia (BPD) is a common cause of pulmonary disease in preterm infants. The soluble receptor for advanced glycation end products (sRAGE) is implicated in the development of various pulmonary diseases. The objectives of the current study were to investigate perinatal factors associated with serum sRAGE levels at birth and to establish whether serum sRAGE could be a biomarker for BPD. This retrospective single-center study was conducted at Fukushima Medical University Hospital's Department of Pediatrics Neonatal Intensive Care Unit from April 2014 to September 2020. Mechanically ventilated or oxygenated neonates born at <32 weeks gestational age and healthy control neonates were included in this study. Serum sRAGE levels in cord blood were measured using an enzyme-linked immunosorbent assay. Eighty-four preterm infants born at <32 weeks and 40 healthy infants were identified. The 84 born at <32 weeks were categorized as BPD (n = 34) or non-BPD (n = 50) neonates. The median gestational age (GA) and birthweight (BW) were significantly lower in BPD vs. non-BPD neonates (24.4 vs. 27.6 weeks, P < 0.001, 634 vs. 952 g, P < 0.001, respectively). Serum sRAGE at birth in all 124 preterm and term infants significantly correlated with BW (r = 0.417, P < 0.0001) and GA (r = 0.415, P < 0.0001). Among those born at <32 weeks, median serum sRAGE levels at birth were significantly lower in infants with BPD than without (1,726 vs. 2,797 pg/mL, P = 0.0005). Receiver operating characteristic analysis for sRAGE levels at birth in infants with and without BPD revealed that the area under the curve was 0.724 (95% confidence interval 0.714–0.834, P = 0.001). However, serum RAGE levels were not associated with severity of BPD. Serum sRAGE levels at birth were significantly correlated with BW and GA. Furthermore, serum sRAGE levels at birth could serve as a biomarker for predicting BPD, but not its severity.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107130105488ZK.pdf 739KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:5次