| Micro & nano letters | |
| Indium nitride humidity sensing devices with microwave resonant property | |
| article | |
| Chih Chin Yang1  | |
| [1] Department of Microelectronics Engineering, National Kaohsiung Marine University | |
| 关键词: indium compounds; III-V semiconductors; wide band gap semiconductors; humidity sensors; X-ray diffraction; Hall effect; resonant tunnelling; Raman spectra; phonons; negative resistance; current density; moisture; high-frequency effects; indium nitride humidity sensing devices; microwave resonant property; X-ray diffraction spectrum; (0002) atomic plane; hexagonal compound; p-type compound; Hall coefhcient; n-type substrate; p-n sensing device; resonant tunnelling property; Raman spectrum; longitudinal optical phonon mode; transverse optical phonon mode; polar mode; negative differential resistance effect; current density; linear region; relative humidity measurement; InN; | |
| DOI : 10.1049/mnl.2013.0679 | |
| 学科分类:计算机科学(综合) | |
| 来源: Wiley | |
PDF
|
|
【 摘 要 】
Objective: To demonstrate the use of a combination of spinal and caudal epidural anesthesia instead of general for prolonged urologic procedures. The technique involves single shot spinal anesthesia (SA) followed by placement of a caudal epidural catheter for prolongation of surgical anesthesia when the effects of SA dissipate. Methodology: We retrospectively report the successful use of the technique in six infants undergoing ureteral reimplantation with a surgical duration of 110 to 166 min (mean 129 min, median 126.5 min). Results: Combined spinal and caudal epidural anesthesia was successful in all 6 infants. In one infant, SA provided surgical anesthesia for the duration of the case so the caudal epidural catheter was not dosed. Sedation was provided by dexmedetomidine with an initial bolus dose (0.6-1.5 μg/kg) in all 6 patients. Five of the 6 patients then received an infusion of dexmedetomidine (0.5-1.0 μg/kg/hour). Four of the 5 patients who received a dexmedetomidine infusion received one additional bolus dose (0.5-1 μg/kg) due to inadequate sedation, patient movement, or increased heart rate. Conclusions: This technique can be used as an alternative to general anesthesia for prolonged urologic procedures. The technique is described and previous reports of combined spinal and caudal epidural anesthesia in infants reviewed.
【 授权许可】
CC BY|CC BY-ND|CC BY-NC|CC BY-NC-ND
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202107100004023ZK.pdf | 425KB |
PDF