期刊论文详细信息
Micro & nano letters
Flexible capacitive pressure sensor based on multi-walled carbon nanotube electrodes
article
Na Shao1  Jian Wu1  Xing Yang2  Jialin Yao2  Yunsheng Shi2  Zhaoying Zhou2 
[1] School of Information Engineering, Nanchang Hangkong University;Department of Precision Instruments, Tsinghua University;State Key Laboratory of Precision Measurement Technology and Instrumentation, Tsinghua University;School of Aeronautical Manufacturing Engineering, Nanchang Hangkong University;Department of Electronics and Optics Engineering, Mechanical Engineering College
关键词: capacitive sensors;    capacitance measurement;    pressure sensors;    pressure measurement;    multi-wall carbon nanotubes;    nanosensors;    electrodes;    microsensors;    dielectric materials;    C;    pressure 0 Pa to 758 Pa;    wearable electronic product;    health monitoring device;    electronic skin;    poly(chloro-p-xylylene);    parylene C;    dielectric layer;    micronano structure;    electronic property;    mechanical property;    MWNT;    sandwich-like structure;    multiwalled carbon nanotube electrode;    flexible capacitive pressure sensor;   
DOI  :  10.1049/mnl.2016.0529
学科分类:计算机科学(综合)
来源: Wiley
PDF
【 摘 要 】

Aim:To evaluate the use of perfusion index for diagnosis of abnormal collateral hand circulation (CHC), in comparison with the modified Allen test and pulse oximetry using Doppler ultrasonography as a reference test. Methodology: Forty two (84 hands) healthy volunteers were randomly selected for our study. Adequacy of the collateral hand circulation during occlusion of the radial artery was assessed in each hand using four tests by four expert investigators, one for each test: (I) Modified Allen test (2) Perfusion index (3) Pulse oximetry, and (4) Doppler ultrasonography being the standard test. Results: The Doppler ultrasonography (the standard test) diagnosed abnormal CHC in 3 hands (3.5%). The modified Allen test showed abnormal CHC in 16 hands (19%), with sensitivity100%, specificity 78% and positive predictive value 18.7% when compared with the standard Doppler ultrasonography. Also pulse oximetry method indicated abnormal CHC in 4 hands (4.7%) with sensitivity100% specificity 98% and 75% positive predictive value. ROC analysis showed that > 65.7% reduction in the perfusion index diagnosed abnormal CHC with 100% sensitivity, 98.8% specificity and 75.5% positive predictive value using Doppler ultrasonography as a reference test. Conclusion: Using Doppler ultrasonography as a reference test, perfusion index is a reliable objective test for diagnosis and prediction of abnormal CHC, with high sensitivity, specificity, and accepted positive predictive value.

【 授权许可】

CC BY|CC BY-ND|CC BY-NC|CC BY-NC-ND   

【 预 览 】
附件列表
Files Size Format View
RO202107100003528ZK.pdf 273KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:3次